140
4.2.14 MP Tray Paper Load
4.2.14.1 Paper Load Cover Removal
1.
Open the standard MP tray.
2.
Remove 1 screw securing the Paper Load Cover.
3.
Release 4 hooks securing the Paper Load Cover to the standard tray.
Figure 4-34. Paper Load Cover Removal
4.2.14.2 MP Tray Paper Load Solenoid Removal
1.
Open the standard MP tray.
2.
Remove the Paper Load Cover. (See “Paper Load Cover Removal” on
page -140.)
3.
Disconnect the harness for the MP Tray Paper Load Solenoid from the
connector.
4.
Remove 1 screw securing the MP Tray Paper Load Solenoid.
Figure 4-35. Manual Feed Tray Paper Load Solenoid Removal