EPSON AcuLaser C2000
Revision C
Disassembly and Assembly
Disassembling Procedure
145
4.2.19 Developer Mechanism
4.2.19.1 Toner Empty Sensor Removal
1.
Remove the Front Cover. (See “Front Cover Removal” on page -123.)
2.
Remove the Front Inner Cover. (See “Front Inner Cover Removal” on
page -124.)
3.
Remove the connector of the Toner Empty Sensor.
4.
Remove 2 screws securing the Toner Empty Sensor to the main
frame.
Figure 4-43. Toner Empty Sensor Removal
4.2.19.2 Front Side Rack Bearing Removal
1.
Remove the Toner Empty Sensor.
2.
Remove 3 screws securing the Front Side Rack Bearing.
Figure 4-44. Front Side Rack Bearing Removal