EPSON AcuLaser C1900/AcuLaser C900
Revision B
Disassembly and Assembly
Printer Main Parts Disassembly and Assembly
192
4.5.11 Multi Purpose Tray
1.
Remove the Upper Front Cover. (p.177)
2.
Remove the Top Cover. (p.177)
3.
Remove the Front Door. (p.178)
4.
Remove the Left Cover. (p.179)
5. Remove the Switch Box. (2 screws)
(See
“Figure 4-35 (p.192)”)
6. Remove the Multi Purpose Tray.
(1 C-ring)
(See
“Figure 4-36 (p.192)”)
Figure 4-35. Switch Box Removal
Figure 4-36. Multi Purpose Tray Removal
C H E C K
P O I N T
Remove the Switch Box while disengaging the one hook from the
frame.
C A U T I O N
The actuator of the Paper Empty Sensor is passing through the tray. If
you remove the tray with the actuator left passing through, the
actuator will be broken.
To avoid breaking the actuator, after disengaging the Multi Purpose
Tray from the Tray Bottom Cover, pull off the Multi Purpose Tray
while pressing the actuator with your hand.
Summary of Contents for AcuLaser C1900
Page 1: ...EPSON AcuLaserC1900 AcuLaserC900 A4 Color Page Printer SERVICE MANUAL ROSCO SEPG02003 ...
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 87: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 122: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 166: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 208: ...C H A P T E R 5 ADJUSTMENT ...
Page 217: ...C H A P T E R 6 MAINTENANCE ...
Page 219: ...C H A P T E R 7 APPENDIX ...
Page 260: ......
Page 261: ......
Page 262: ......
Page 263: ......
Page 264: ......
Page 265: ......
Page 266: ......
Page 267: ......
Page 268: ......
Page 269: ......
Page 270: ......