EPSON AcuLaser C1900/AcuLaser C900
Revision B
Disassembly and Assembly
Printer Main Parts Disassembly and Assembly
189
4.5.8 Cleaner Pressure Flapper Solenoid (SL4)
1.
Remove the Upper Front Cover. (p.177)
2.
Remove the Top Cover. (p.177)
3.
Remove the Rear Cover. (p.178)
4.
Remove the Left Cover. (p.179)
5.
Remove the Power Supply Fan Motor (M4). (p.185)
6.
Remove the High Voltage Unit (HV). (p.188)
7. Remove the Cleaner Pressure Flapper Solenoid. (1 screw)
(See
“Figure 4-27 (p.189)”)
Figure 4-27. Removing the Cleaner Pressure Flapper Solenoid
Figure 4-28. Mounting Position of Cleaner Pressure Flapper Solenoid
When installing the Cleaner Pressure Flapper Solenoid, adjust the
following positions:
Position of the cam inside the frame
Position of the solenoid claw