35
1.2.6 Storage and Transport Environments of the
Packaged Printer Main Unit and Optional Products
NOTE:
Including Bundled Consumables
Temperature and Humidity Conditions
Note *1: 35 ~ 55
°
C when the DEVELOPER cartridges and photoconductor unit are
uninstalled.
*2: Condensation must be avoided.
Barometric Pressure for Storage (Altitude):741 ~ 1013 hPa
NOTE:
1 613 ~ 1013 hPa when the DEVELOPER cartridges and
photoconductor unit are uninstalled.
Dropping
: No damage must occur for packaged products in dropping from
52 cm height, and in 1 corner, 3 edges, 6 sides of direction.
Compliant with the EPSON transport assessment standard (T-
AE05-001-001).
Vibration
: Must conform to the JIS Z0200-1999 level 1
Compression
: Refer to Packing Specifications.
Size
: Refer to Packing Specifications.
Weight
: Refer to Packing Specifications.
Loading
: Refer to Packing Specifications.
Pallet Size
: Refer to Packing Specifications.
1.2.7 Electrical Feature
In the following items, all options are excluded.
Fast Transient / Burst (AC Line Noise)
The following conditions shall be met in the “IEC61000-4-4” compliant evaluation.
1kV
: No error excepting minor dot errors.
1.8kV
: No Component damaged.
Instantaneous Outages
DIP 100% of instantaneous outages (at rated voltage - 10%) for 1-cycle
No deterioration in the printing quality.
The following condition shall be met in the “IEC61000-4-11” compliant
evaluation.
• 95% lowered 0.5 cycle
: No error excepting minor dot errors.
• 30% lowered 25 cycle
: No component damaged.
• 95% lowered 250 cycle
: No component damaged.
Resistance to Static Electricity
The following condition shall be met in the “IEC61000-4-2” compliant evaluation.
Contact discharge 8 kV
: No error in any devices.
Discharge into the air 15 kV : No error in any devices.
Inrush Current
1/2-cycle
: 50 A or less (0-peak) (At 23
°
C or higher)
<Reference: Actually measured value including heater inrush>
• 100V: 1/2 cycle 88.0 A (0-peak)
• 120V: 1/2 cycle 66.0 A (0-peak)
• 220V: 1/2 cycle 35.6 A (0-peak)
• 240V: 1/2 cycle 38.0 A (0-peak)
(
By cold start at 23
°
C
)
Insulation Resistance
10 M
Ω
or more
Table 1-19.
Temperature
Humidity
Warranty period
Normal Conditions
0 to 35
°
C
30 to 85% RH
*2
18 month after production
Severe Conditions
High temperature:
35 ~ 40
°
C
*1
Low temperature:
-20 ~ 0
°
C
High humidity:
85 ~ 95% RH
*2
Low humidity:
10 ~ 30% RH
*2
1/30 of 18 months
Summary of Contents for AcuLaser C1900
Page 1: ...EPSON AcuLaserC1900 AcuLaserC900 A4 Color Page Printer SERVICE MANUAL ROSCO SEPG02003 ...
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 87: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 122: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 166: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 208: ...C H A P T E R 5 ADJUSTMENT ...
Page 217: ...C H A P T E R 6 MAINTENANCE ...
Page 219: ...C H A P T E R 7 APPENDIX ...
Page 260: ......
Page 261: ......
Page 262: ......
Page 263: ......
Page 264: ......
Page 265: ......
Page 266: ......
Page 267: ......
Page 268: ......
Page 269: ......
Page 270: ......