SM-Ethernet User Guide
97
Issue: 7
Sa
fety
In
Me
cha
nical
El
Get
tin
Pr
We
b p
FTP
A
Di
Adv
Q
Glossa
In
Table 11.3 Duplex mode
If this parameter value is changed, then a module save should be performed
(
xx.00
=1000 or
xx.00
=1001 if using a DC supply to power the drive) followed by
resetting the SM-Ethernet module (
MM.32
=ON) to activate the change.
11.4.16SM-Ethernet enable auto-crossover detection
This parameter is used to determine if the module should use auto-crossover detection
or use a standard (
patch
) cable. If it is set to 0 you either need a cross-over cable or you
need to connect via a switch.
Table 11.4 Crossover detection
If this parameter value is changed, then a module save should be performed
(
xx.00
=1000 or
xx.00
=1001 if using a DC supply to power the drive) followed by
resetting the SM-Ethernet module (
MM.32
=ON) to activate the change.
11.4.17SM-Ethernet actual baud rate
Displays the baud rate at which SM-Ethernet is operating.
Table 11.5 Actual baud rate
11.4.18SM-Ethernet actual duplex mode
Displays the duplex mode that SM-Ethernet is currently using.
Pr MM.42
bit/s
0
Auto-detect.
1
full duplex.
2
half duplex.
SM-Ethernet - Enable crossover detection
Pr
MM.43
Default
0 (disabled)
Range
0 to 1
Access
RW
Pr MM.43
Crossover detection
0
Disabled.
1
Enabled.
SM-Ethernet Actual baud rate
Pr
MM.44
Default
0
Range
0 to 2
Access
R
Pr MM.44
Actual baud rate
0
Baud rate not set.
1
10Mbs.
2
100Mbs.
SM-Ethernet Actual duplex mode
Pr
MM.45
Default
0
Range
0 to 2
Access
R
Summary of Contents for SM-Ethernet