The filling machine does not start and no liquid
comes out of the filler head.
Check that the machine is powered at the right
voltage. Do not use extension leads of insufficient
section which could cause voltage drops.
Check any safety devices of the electricity system
Check that the compressor is turned on and that
the air tubes are open.
Check that the air tube is connected to the
pneumatic valve.
Check that the switch is in the ON position.
Check that the magnetic-thermic switch inside the
control panel is in the right position.
Check that the pump is sucking up the liquid and if
necessary close the by-pass.
Position the machine in a dry place, protecting it from bad weather and damp
Do not use the machine to decant inflammable or explosive liquids or in an explosive
atmosphere, since the motor is not explosion-proof
The temperature of the liquids to be decanted must be between +5 °C and 60 °C; higher
temperatures cause a general deterioration of the overall performance of the machine
The noise levels observed are within the limits foreseen by the directive 2006/42 EEC (<85dB)
Before starting up the machine make sure that it has not been subject to damage during transport
(breakages or dents) which could prejudice its functioning
Never plug in the machine, use the commands or perform any other operation on the electrical
parts with wet hands
Do not remove the protective casing when the machine is functioning or being washed.
Read this manual carefully and thoroughly before using the machine and keep it to hand for any
future reference.
Enoitalia S.r.l. is not responsible for any damage deriving from modifications made to the
machine by third parties.
Enoitalia S.r.l. reserves the right to make manufacturing modifications at any moment without
being under any requirement to communicate such.
Enoitalia S.r.l.
Via Provinciale Pisana, 162 Fraz. Pieve a Ripoli
50050 Cerreto Guidi- (FI)
Tel: +39 0571588031 Fax:+39 0571588080
6. WARNINGS
Summary of Contents for BB 20
Page 17: ......