Select the option PARAMETRI on the first screen, and the following screen will appear with the
values to be set:
GESTIONE BLOCCO: it is a parameter that allows to control the lock piston of the filling
head, allowing you to disable it if necessary. WARNING: We suggest you contact technical
support before changing this parameter
GESTIONE VUOTO
”:
it indicates the vacuum time applied on the bags. You can set how
many seconds vacuum..
GESTIONE AZOTO 1: it indicates the nitrogen injection time applied to the bags at the
beginning of the filling.
GESTIONE AZOTO 2: it indicates the nitrogen injection time applied to the bags at the end
of the filling.
Press AVANTI to see the second screen:
ESCI
CONTALITRI (K FACTOR)
90
CORREZIONE LITRI
AUTOTUNING
START
PASSWORD
PARAMETRI CICLO
0.00
IMP\L
L
0.0
L
CONTALITRI K FACTOR: it is the parameter that allows for calibration of the meter, setting
the pulses per liter
CORREZIONE LITRI: it is the parameter for a fine calibration. Must be used to correct
values under 0.15 lt
PARAMETRI CICLO
ESCI
GESTIONE BLOCCO
0.0 SEC
GESTIONE VUOTO
GESTIONE AZOTO 1
GESTIONE AZOTO 2
3 SEC
0.0 SEC
1.5 SEC
AVANTI
SI
SI
NO
SI