Select the option RICETTE , and the following screen will appear with the values to be set : after the
setting of all the previous parameter , it is possible store the values combining them with a recipe that
can be recalled at a later time.
:
ESCI
INTR. NOME
NUMERO RICETTE
0.00
CARICA
SALVA
Select the option PASSWORD, and the following screen will appear with the values to be set :
following we have indicate the value of UTENTE and the PASSWORD to be used to enter inside
the protected menu
ESCI
UTENTE
PASSWORD
PASSWORD
571
2
For the correct functioning of the machine and verification of filling precision a scales or
graduated recipient is needed.
The parameter used to adjust the filling is “CONTALITRI, K FACTOR» while the “CORREZIONE
LITRI ” parameter is for the fine-adjustment of filling.
The K factor expresses a measure of “steps” used by the sensor to measure 1 litre of liquid decanted.
This factor varies in relation to the type of fluid to be decanted, the type of pump used, the length and
diameter of the tubes and the pressure exerted by the liquid inside the tubes. At the moment of
purchase of the machine the K value is set at 160; this value should be INCREASED if the weight of
the bag being filled is less than the theoretical weight of the quantity to be filled. Vice versa it should
be REDUCED if the weight of the bag being filled is more than the theoretical weight to be filled.
3. ADJUSTMENT
DIS. 16
DIS. 17
Summary of Contents for BB 20
Page 17: ......