Code: I.H4.V10.3003
Installation and Maintenance Manual
Version: 07
17 / 66
Ennera Energy and Mobility, S.L.
This document contains confidential information which is property of Ennera Energy and Mobility, S.L. The copy, transmission or use by other people, of the whole document or
part of its contents, is not allowed without written permission from Ennera Energy and Mobility S.L.
5.3.
Ennera design 2-section tower assembly
1.
In case the tower is a 2 section
tower (plus the cylindrical pipe), the
interference distance is 705mm.
2.
The assembly process is the same
than multi-section tower.
5.4.
Ambor design 3 section tower assembly
1.
In case the tower is an Ambor design
3 section tower, the assembly process is
the same.
2.
The interference (slip) between the
first and second tower sections is 700 ±
240mm.
3.
The interference (slip) between the
first and second tower sections is 650 ±
240mm.
5.5.
Lifting mechanism
1.
The tractel fixing point should be
located 7m away from the foundation
area, aligned with the tower. See Annex
6.
2.
The tractel fixing point (EL-1) should
have a disk of 150mm diameter and a
length of 1.5m.
705mm