background image

Serial Amp Control Port was developed exclusively for ENGL amps. No other footboard
will work and in fact is likely to damage the footboard or the amp's circuitry!
You can use the ENGL Z11-S.A.C. MIDI Switcher to integrate the amp straight into a
MIDI system. You can also opt to control two amps in parallel using the Z11-S.A.C.
MIDI Switcher and MIDI commands. The Z11-S.A.C. Switcher is equipped with six
switching loops (accessed via three stereo jacks) and the S.A.C. Out (stereo jack) for
precisely this purpose!

on/off and

on/off.

on/off

/off

and

.

Master A or B

FX Loop

Noise Gate

FX Loop

FX Loop

Master A/B

Shape (Contour)

Master A/B

20 Footswitch: FX Loop, Noise Gate

21 Footswitch: Master A/B, Shape (Contour, E650-2)

22 Footswitch: Clean/Lead, Gain Low/High

Use this jack to connect a conventional footswitch with two switching functions, for
example, the ENGL Z-4 (2 x off/on - Single Pole Single Throw or SPST for short). This
type of footswitch lets you access

One of the

two switches enables or bypasses

, while the other switches the Noise Gate on

and off (in the Lead channel with High Gain engaged only).
Note also: A footswitch may be equipped with LEDs indicating the given switching
status. Each of the two switches is provided with approx. 10 milliamperes current,
which suffices to power a standard LED. The jack's mono terminal controls

, while the stereo terminal controls

on

(for pin assignments, see

page 22).

Use this jack to connect a conventional footswitch with two switching functions, for
example, the ENGL Z-4 (2 x off/on - Single Pole Single Throw or SPST for short). This
type of footswitch lets you access

One of the two

switches activates

, while the other switches the voicing feature

; it alters the mid range frequency response in the EQ section of the preamp.

Plugging a footswitch into this jack disables onboard Master A/B (via button 11) and
Shape (Contour) switching.
Note also: A footswitch may be equipped with LEDs indicating the given switching
status. Each of the two switches is provided with approx. 10 milliamperes current,
which suffices to power a standard LED. The jack's mono terminal selects

,

while the stereo terminal controls the Shape (Contour) feature (for pin assignments,
see page 22).

Use this jack to connect a conventional footswitch with two switching functions, for
example, the ENGL Z-4 (2 x off/on - Single Pole Single Throw or SPST for short). This
type of footswitch lets you access the two channels Clean and Lead.
This type of footswitch lets you access the two channels and

. One of

the two switches activates

or

; the other activates

or

.

Plugging a footswitch into this jack disables onboard channel (12) switching and

(11).

Note also: A footswitch may be equipped with LEDs indicating the given switching
status. Each of the two switches is provided with approx. 10 milliamperes current,
which suffices to power a standard LED. The jack's mono terminal selects

,

while the stereo terminal controls the

feature (for pin assignments, see

page 20).

Noise Gate

Shape

(Contour)

Gain Low/High

Clean

Lead

Low Gain

High Gain

Gain

Low/High

Clean/Lead

Gain Low/High

12

Summary of Contents for Artist Edition E651

Page 1: ...E650 E651 E653 Ritchie Blackmore Artist Edt Operator s Manual...

Page 2: ...Loop off on Noise Gate S A C Port FX Loop Send Return Balance Dry Effect Threshold Off Lo Hi Noise Gate Lead Channel 100 Watts All tube Guitar Amp Head Ritchie Blackmore Signature TYPE E650 Artist Ed...

Page 3: ...16 Ohms Poweramp Output Cabinet options Power Amp section Master A B Mains Mains Fuse S A C Port for Z 9 or Z11 S A C Footswitch Ports You ll find an ancillary pamphlet accompanying this owner s manu...

Page 4: ...es and applications There are few more handy features to rave about This amp sports our Serial Amp Control Port or S A C Port for short for connecting remote control units like the ENGL Z 9 Plug an EN...

Page 5: ...e for the Clean channel and the Shape Contour button in the EQ section for and You can footswitch these knobs to activate two different power amp volume settings on the fly without twisting a knob It...

Page 6: ...ation due to high frequency loss use the shortest cords feasible as a rule the shorter the cord the less susceptible it is to high frequency attenuation Gain control for the tube amp s extraordinary v...

Page 7: ...knob settings beyond the 1 o clock s position at high output power in order to prevent interaction between guitar and speakers that possibly causes undesirable feedback Moreover the noise floor rises...

Page 8: ...e may also be switched using a Z 9 Custom Footswitch connected to the S A C Port 19 or a footswitch connected to jack 21 The button 8 on the amp s front panel is disengaged when you switch the Shape C...

Page 9: ...wer amp output The green LED to the right of the knob lights up to indicate Master B is enabled and determining the master level The Master B knob is selected whenever you activate via button 11 and n...

Page 10: ...onsiderable wear The amp is ready to run when you flip the Standby switch because the tubes are already warm and don t require time to heat up For breaks of 20 minutes and longer I recommend that you...

Page 11: ...ther clever switching concept it features four switches that afford you direct access to and in combination with the two Gain stages and Clean Low Gain Clean High Gain Lead Low Gain and Lead High Gain...

Page 12: ...conventional footswitch with two switching functions for example the ENGL Z 4 2 x off on Single Pole Single Throw or SPST for short This type of footswitch lets you access One of the two switches acti...

Page 13: ...keep a lid on extraneous noise during short breaks It s in the nature of high gain rigs to generate undesirable peripheral noise in overdriven high gain channels This is attributable to the physical...

Page 14: ...p signal is routed through with no processed signal 0 wet balance added to the mix Twist the knob clockwise to blend in the processed signal parallel passive wet balance 1 99 depending on knob positio...

Page 15: ...ol down before you transport it Ten minutes or so will spare the tubes Tubes take some 20 seconds to warm up after you switch the power on and about two to three minutes before they are able to pump o...

Page 16: ...ply switch the amp off and on again If a reset doesn t solve the problem there is a defect in the control system probably on the logic board holding the microcontroller or merely a faulty contact on o...

Page 17: ...efect In this case be sure to take the preamp to an authorized professional service center Is there a connection for example via a shielded circuit between the amp and another device that is grounded...

Page 18: ...ly to 4 8 and 16 ohms T slo blo M medium blo ECC83 F Q input tube EL34 E651 6L6GC E650 2 matched sets Replace tubes with selected sets only Refer to page 20 for pin assignments Replace these with fuse...

Page 19: ...d on _ _ _ _ _ _ _ 20 _ _ _ Replaced by _ _ _ _ _ _ _ _ _ _ _ _ _ _ Replaced tubes _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Reason _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 20: ...gh Gain via jack via jack 22 A switch connected to this terminal T controls FX Loop off bypassed on enabled via jack 20 Master A B Master A control Master B control via jack 21 Clean Lead Clean channe...

Page 21: ...tch The ENGL Z 4 dual footswitch 1 2 2 2 Serial Amp Control Port CAUTION Connect Custom Footswitch Z 9 Only Clean Lead Gain Low High Footswitch Master A B Mid Shape Contour FX Loop off on Noise Gate S...

Page 22: ...rently or newly selected configuration For example if LED 3 flashes when the Z 9 s Setup routine is activated then the Artist Edition R B S Amp s switching feature is currently assigned to the corresp...

Page 23: ...Space for User Notes 23...

Page 24: ...www engl amps com...

Reviews: