background image

different playing styles and musical genres to great dramatic effect. What's more, you
can use the Clean channel

or

mode for rhythm or cleaner lead lines

and the Lead channel's overdriven preamp stage for power chords and soloing, and go
from soft to loud at the touch of a button. Beyond that, you can also broaden the
volume and tonal ranges by working your guitars' volume knob. If your arsenal
includes MIDI gear - for instance, the Z11-S.A.C. ENGL MIDI Switcher in combination
with the Z-9 Custom Footswitch - you may use the amp's Master A/B circuit to swiftly
and conveniently set the power amp's volume to two different levels, and then access
these volume presets in combination with preamp voicing features such as

. The mind boggles…

Power amp standby switch: Use this switch to silence (0 position) the amp when you
take longer break. The amp's tubes stay nice and toasty, and the amp is ready to roll
immediately when you ramp it back up to full power.

I suggest you get into the habit of using standby during short breaks. In this mode,
current is not piped through the power tubes, so they don't get as hot (due to the lack
of anode dissipation) and are spared considerable wear. The amp is ready to run when
you flip the Standby switch because the tubes are already warm and don't require time
to heat up. For breaks of 20 minutes and longer, I recommend that you switch the amp
off in order to conserve energy.

Mains power on/off.

ensure that the Stand By switch (15) is set to

(0 position) before

you switch the amp on. Let the tubes heat up for about 30 seconds before you activate
the power amp. This procedure spares the tubes.

Plug the mains cord in here. For European models, use a standard non-heating
equipment connector cable.

Low Gain

High Gain

Shape

(Contour)

Stand By

15 Stand By

A tip from the designer:

16 Power

CAUTION: After an extended period of operation and higher ambient temperatures
the amps's chassis can become very hot, therefore avoid touching the rear panel
surface !

Mains Connector (

CAUTION: Make sure you use an intact mains line cord with a grounded plug!
Before you power the amp up, ensure the voltage value printed alongside the mains
socket is the same as the current of the local power supply or wall outlet.
Please also heed the guidelines set forth in the separately included pamphlet,

.

Rear Panel Features

Instructions for the Prevention of Fire, Electrical Shock and Injury

Please note:

On page 2 of the manual, you'll find diagrams of the front and rear panels.

17

AC Power Inlet; IEC - C14 connector)

10

Summary of Contents for Artist Edition E651

Page 1: ...E650 E651 E653 Ritchie Blackmore Artist Edt Operator s Manual...

Page 2: ...Loop off on Noise Gate S A C Port FX Loop Send Return Balance Dry Effect Threshold Off Lo Hi Noise Gate Lead Channel 100 Watts All tube Guitar Amp Head Ritchie Blackmore Signature TYPE E650 Artist Ed...

Page 3: ...16 Ohms Poweramp Output Cabinet options Power Amp section Master A B Mains Mains Fuse S A C Port for Z 9 or Z11 S A C Footswitch Ports You ll find an ancillary pamphlet accompanying this owner s manu...

Page 4: ...es and applications There are few more handy features to rave about This amp sports our Serial Amp Control Port or S A C Port for short for connecting remote control units like the ENGL Z 9 Plug an EN...

Page 5: ...e for the Clean channel and the Shape Contour button in the EQ section for and You can footswitch these knobs to activate two different power amp volume settings on the fly without twisting a knob It...

Page 6: ...ation due to high frequency loss use the shortest cords feasible as a rule the shorter the cord the less susceptible it is to high frequency attenuation Gain control for the tube amp s extraordinary v...

Page 7: ...knob settings beyond the 1 o clock s position at high output power in order to prevent interaction between guitar and speakers that possibly causes undesirable feedback Moreover the noise floor rises...

Page 8: ...e may also be switched using a Z 9 Custom Footswitch connected to the S A C Port 19 or a footswitch connected to jack 21 The button 8 on the amp s front panel is disengaged when you switch the Shape C...

Page 9: ...wer amp output The green LED to the right of the knob lights up to indicate Master B is enabled and determining the master level The Master B knob is selected whenever you activate via button 11 and n...

Page 10: ...onsiderable wear The amp is ready to run when you flip the Standby switch because the tubes are already warm and don t require time to heat up For breaks of 20 minutes and longer I recommend that you...

Page 11: ...ther clever switching concept it features four switches that afford you direct access to and in combination with the two Gain stages and Clean Low Gain Clean High Gain Lead Low Gain and Lead High Gain...

Page 12: ...conventional footswitch with two switching functions for example the ENGL Z 4 2 x off on Single Pole Single Throw or SPST for short This type of footswitch lets you access One of the two switches acti...

Page 13: ...keep a lid on extraneous noise during short breaks It s in the nature of high gain rigs to generate undesirable peripheral noise in overdriven high gain channels This is attributable to the physical...

Page 14: ...p signal is routed through with no processed signal 0 wet balance added to the mix Twist the knob clockwise to blend in the processed signal parallel passive wet balance 1 99 depending on knob positio...

Page 15: ...ol down before you transport it Ten minutes or so will spare the tubes Tubes take some 20 seconds to warm up after you switch the power on and about two to three minutes before they are able to pump o...

Page 16: ...ply switch the amp off and on again If a reset doesn t solve the problem there is a defect in the control system probably on the logic board holding the microcontroller or merely a faulty contact on o...

Page 17: ...efect In this case be sure to take the preamp to an authorized professional service center Is there a connection for example via a shielded circuit between the amp and another device that is grounded...

Page 18: ...ly to 4 8 and 16 ohms T slo blo M medium blo ECC83 F Q input tube EL34 E651 6L6GC E650 2 matched sets Replace tubes with selected sets only Refer to page 20 for pin assignments Replace these with fuse...

Page 19: ...d on _ _ _ _ _ _ _ 20 _ _ _ Replaced by _ _ _ _ _ _ _ _ _ _ _ _ _ _ Replaced tubes _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Reason _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 20: ...gh Gain via jack via jack 22 A switch connected to this terminal T controls FX Loop off bypassed on enabled via jack 20 Master A B Master A control Master B control via jack 21 Clean Lead Clean channe...

Page 21: ...tch The ENGL Z 4 dual footswitch 1 2 2 2 Serial Amp Control Port CAUTION Connect Custom Footswitch Z 9 Only Clean Lead Gain Low High Footswitch Master A B Mid Shape Contour FX Loop off on Noise Gate S...

Page 22: ...rently or newly selected configuration For example if LED 3 flashes when the Z 9 s Setup routine is activated then the Artist Edition R B S Amp s switching feature is currently assigned to the corresp...

Page 23: ...Space for User Notes 23...

Page 24: ...www engl amps com...