![ENFORCER DP-266-1C3Q Manual Download Page 5](http://html1.mh-extra.com/html/enforcer/dp-266-1c3q/dp-266-1c3q_manual_2411977005.webp)
ENFORCER Wireless Video Door Phone
SECO-LARM U.S.A., Inc.
5
R
es
et
Camera Wiring Diagram:
Sample Application:
COM
N.C.
N.O.
Egress input (N.O., -)
(+)
(–)
PUSH
TO
EXIT
Request-to-exit plate
Electric strike
power supply
Fail-secure
electric strike
To the included AC adapter or
the doorbell's transformer
Negative (-) (black wire)
Positive (+) (red wire)
1
2
3
4
5
6
Camera
6
5
4
3
2
1
The camera is connected to its included AC adapter.
The egress input is connected to a Request-to-Exit Plate. The homeowner can exit the
premises by pressing this button.
The N.O. (normally open) output is wired to an electric lock. The camera and the
Request-to-Exit Plate both activate the strike, allowing entry or egress.
The electric lock's power supply is wired to the COM (common) output.
1.
Positive (+) power input – Connect to the red wire of the included AC adapter or to the positive
wire of the doorbell's power supply.
2.
Negative (-) power input – Connect to the black wire of the included AC adapter or to the
negative wire of the doorbell's power supply.
3.
Egress (N.O.) negative input – Connect to an optional N.O. egress device. The egress device
will activate the relay for the same length as the lock delay. (See the "Unlocking duration"
section in "Programming the Advanced Settings," pg. 11).
4.
N.O. (Normally opened) output – Wire to the lock device for fail-secure operation.
5.
N.C. (Normally closed) output – Wire to the lock device for fail-safe operation.
6.
Common output – Wire to the power supply of the lock device.
NOTE: For 16VAC doorbell installation, wire directly from the doorbell's transformer.
COM
N.C.
N.O.
Egress input (N.O., –)
(–)
(+)
9~16 VAC/
5~16 VDC
Relay
Output