60
Euromax Pellet Stove Installation and Operation Manual
NOTE: IF THE CODE APPEARS MORE THAN THREE TIMES, THE LCD SCREEN WILL
LOCK ITSELF UP.
THIS PELLET STOVE IS EQUIPED WITH MULTIPLE DEVICES TO ENSURE YOUR
SAFETY. IF A WARNING ERROR CODE STOPS YOUR STOVE ON SEVERAL
OCCASIONS, IT IS MORE THAN LIKELY THAT THE STOVE DOES NOT EXHAUST
PROPERLY.
Before resetting the PC-board displaying an error code, do a
COMPLETE stove maintenance as described in this manual.
For an Overheat Code
•
Service the stove COMPLETELY as described in this manual. See section 8
: Maintenance
•
Verify the venting system and all other components mentioned above.
ONCE THE MAINTENANCE DONE, FOLLOW THESE INSTRUCTIONS
After 3 attempts press restart
and then enter the following code
999333555
and press accept. The system will reset.
9.3.7 Hopper Lid Open
v
The hopper lid remained open for more than 3 minutes.
As a security measure, the
auger stops turning and feeding pellets as soon as the hopper lid opens. It will resume
normal operation as soon as the hopper lid is closed. If the hopper lid stays open for more
than 3 minutes, the stove will stop.
v
The hopper lid safety switch is faulty or disconnected.
Make sure that the switch
wiring is properly connected. If it is, the hopper switch may be faulty. Follow steps in the
troubleshooting page (see
Section 9.2 Testing Components
) and verify the proper
function of the safety switch. Replace if necessary.
Summary of Contents for Euromax
Page 63: ...Euromax Pellet Stove Installation and Operation Manual 63 10 Wiring Diagram ...
Page 76: ...76 Euromax Pellet Stove Installation and Operation Manual SECTION B ...
Page 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION C ...
Page 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION D SECTION E ...
Page 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION F SECTION G ...
Page 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION H SECTION I ...