6.1.6 Combustion Settings and Pilot Settings depending on Fuel Quality
6.1.6.1 PILOT ADJUSTMENT (Pilot Settings Adjustment)
The “PILOT ADJUSTEMENT” will allow you to modify default settings by ±5% for auger motor
1 and ±10% for combustion and exhaust fan, but will only apply during pilot cycle:
To restore default setting, select “DEFAULT”.
6.1.6.2 COMBUSTION ADJUSTMENT (Fuel Quality Adjustment)
The “COMBUSTION ADJUSTMENT” will allow you to modify default settings by ±5% for
auger motor 1 and ±10% for combustion and exhaust fan.
To restore default setting, select “DEFAULT”.
Here are some situations where you may want to adjust these components: