Unit Placement
When installing a heating and cooling unit, there are several
items the installer should consider before placing the
equipment.
Service Access
See illustrations in this manual
for recommended unit
clearances.
The installer must verify that all applicable wiring, piping,
and accessories are correct and on the job site. All wiring,
line and low voltage, should comply with the manufacturer’s
recommendations, the National Electrical Code, and all local
codes and ordinances.
All Indoor EME/EMD Modules should be located in an indoor
area were the ambient temperature will remain between 55
o
F
and 95
o
F.
Unit should be located in a way that piping or other
permanently installed fixtures do not have to be removed for
servicing.
Outdoor Unit Installation
This manual describes installation and service procedures for
implementation by Enertech trained specialists.
This is an original manual. It may not be translated without
the approval of Enertech. We reserve the right to make design
modifications without prior notice.
Balance Point Temperature
The balance temperature is the outdoor temperature when
the heat pump’s stated output is equal to the building’s input
requirement. This means that the heat pump covers the whole
building’s output requirement down to this temperature.
Compressor Heater
EAV is equipped with two compressor heaters that heat the
compressor before start-up and when the compressor is cold.
Minimum Outdoor Temperatures
In heating, the minimum outdoor air temperature at which
the unit will operate is -13 deg. F. In cooling, the minimum
temperature is 32 deg. F.
Packaging Disposal
Disposal of the packaging should be completed by the installer.
Removal of all packaging and waste should be done in an
environmentally friendly way. Please recycle responsibly.
Do not dispose of used products with normal household waste.
It must be disposed of at a special waste station or dealer who
provides this type of service. Please recycle responsibly.
Environmental Information
The equipment contains R410A, a fluorinated greenhouse gas
with a GWP value (Global Warming Potential) of 2088. Do not
release R410A into the atmosphere.
Serial Number
The serial number can be found at the bottom left on the rear
cover (see page 6).
Installer Manual
This installer manual must be left with the customer.
⚠
CAUTION
⚠
BEFORE DRILLING OR DRIVING ANY SCREWS INTO
CABINET, CHECK TO BE SURE THE SCREW WILL NOT HIT
ANY INTERNAL PARTS OR REFRIGERANT LINES
⚠
CAUTION
⚠
DO NOT OPERATE THE HEAT PUMP UNIT DURING
BUILDING CONSTRUCTION PHASE.
⚠
NOTICE
⚠
When starting the unit in low ambient conditions, the
compressor heater may need to be active for up to 3 hours
before starting unit.