Enertech Global
5
EAV - EME/EMD Rev. A Models
Installation and Operations Manual
Introduction
This heat pump provides heated and chilled solution as well
as optional domestic water heating capability. Engineering
and quality control is built into every unit. Good performance
depends on proper application and correct installation.
Safety Labeling and Signal Words
The signal words
NOTICE, DANGER, WARNING, CAUTION,
and
Note
are used on product labels and throughout this manual to
identify levels of hazard seriousness.
“NOTICE”
Notification of installation, operation or maintenance
information which is important, but which is NOT hazard related.
“CAUTION”
Indicates a potentially hazardous situation or an
unsafe practice which, if not avoided, COULD result in minor or
moderate injury, product or property damage.
“WARNING”
Indicates a potentially hazardous situation which, if
not avoided, COULD result in death or serious injury.
“DANGER”
Indicates an immediate hazardous situation which, if
not avoided, WILL result in death or serious injury.
“Note”
Used to highlight suggestions which will result in
enhanced installation, reliability, or operation.
Inspection
Upon receipt of any equipment, carefully check the shipment
against the packing slip and the freight company bill of lading.
Verify that all units and packages have been received. Inspect
the packaging of each package and each unit for damages.
Ensure that the carrier makes proper notation of all damages or
shortage on all bill of lading papers. Concealed damage should
be reported to the freight company within 5 days. If not filed
within 5 days the freight company can deny all claims.
Note:
Notify Enertech Global Customer Service Department
of all damages within 5 days. It is the responsibility of the
purchaser to file all necessary claims with the freight company.
Unit Protection and Storage
Protect units from damage and contamination due to plastering
(spraying), painting and all other foreign materials that may be
used at the job site. Keep all units covered on the job site with
either the original packaging or equivalent protective covering.
Cap or recap unit connections and all piping until the unit is
installed. Precautions must be taken to avoid physical damage
and contamination which may prevent proper start-up and may
result in costly equipment repair.
Units should be stored in an upright position at all times and
should not be stacked unless specially noted on the packaging.
Pre-Installation
Special care should be taken in locating the unit. Installation
location chosen should include adequate service clearance
around the unit. The Indoor Module should be located in a
conditioned space where the ambient temperature remains
between 55
o
F and 95
o
F with a maximum RH of 78-80%.
It should be located in a way that piping or other permanently
installed fixtures do not have to be removed for servicing.
Pre-Installation Steps
•
Compare the electrical data on the unit nameplate with
packing slip and ordering information to verify that the
correct unit has been shipped.
•
Inspect all electrical connections and wires. Connections
must be clean and tight at the terminals, and wires should
not touch any sharp edges or copper pipe.
•
Verify that all refrigerant tubing is free of dents and kinks.
Refrigerant tubing should not be touching other unit
components.
•
Before unit start-up, read all manuals and become familiar
with unit components and operation. Thoroughly check the
unit before operating.
•
Fill out the unit installation form in the back of this IOM.
Consumer Instructions
The dealer should instruct the consumer in the proper
operation, maintenance, thermostat and indicator lights.
Also provide the consumer with the manufacturer’s Owner’s
Manual for the equipment being installed.
Enertech Global D-I-Y Policy
Enertech Global’s heat pumps and system installations may
include electrical, refrigerant and/or water connections. Federal,
state and local codes and regulations apply to various aspects
of the installation. Improperly installed equipment can lead
to equipment failure and health/safety concerns. For these
reasons, only qualified technicians should install an Enertech
Global built system.
Because of the importance of proper installation, Enertech
Global does not sell equipment direct to homeowners. Internet
websites and HVAC outlets may allow for purchases directly by
homeowners and do-it-yourselfers, but Enertech Global offers
no warranty on equipment that is purchased via the internet or
installed by persons without proper training.
Enertech Global has set forth this policy to ensure installations
of Enertech Global systems are done safely and properly. The
use of well-trained, qualified technicians helps ensure that your
system provides many years of comfort and savings.
⚠
CAUTION
⚠
THE EME/EMD SERIES EQUIPMENT IS DESIGNED FOR
INDOOR INSTALLATION ONLY (THE EAV EQUIPMENT
IS DESIGN FOR OUTDOOR INSTALLATION). DO NOT
INSTALL THE EME/EMD MODULE OR STORE IN A
CORROSIVE ENVIRONMENT OR IN A LOCATION
WHERE TEMPERATURE AND HUMIDITY ARE SUBJECT
TO EXTREMES. EQUIPMENT IS NOT CERTIFIED FOR
OUTDOOR APPLICATIONS. SUCH INSTALLATION WILL
VOID ALL WARRANTIES.
Section 2: Installation Introduction