Operation
5.0 LED Indicators
The LEDs on the front of the ME-SBC
TM
are there to communicate the status of the
ME-SBC
TM
, Faults, and Warnings. Use the table below to determine the status of
the device.
The Reverse Polarity LED indicates that the wiring to the Main Terminal is incor-
rect. Correct the reverse polarity and the LED should turn off.
ME-SBC
TM
STATUS and DISCONNECTED LED Indicators
Status LED
(bi-color Red or
Green)
Disconnected
LED (Yellow)
Description
OFF
OFF
No Power
OFF
ON
Low Voltage Disconnect (LVD).
Disconnected
OFF
Slow Blink
High Voltage Disconnect (HVD).
Disconnected
Solid Green
OFF
FET switch connects MAIN and AUX
connect voltage requirement is met
on either battery, connected
Slow
Blinking Green
OFF
FET Temp > 80C – goes to 50% duty
cycle for charging, connected
Slow Blinking
Red
ON
FET Temp > 90C, temperature
disconnect. Auto reconnect when
FET temperature falls below 70C
and if voltage meets “connect” spec.
Disconnected
Fast
Blink
Red
OFF
Average current > 20 Amp. Auto-
reconnect after 10 Secs if voltage
meets “connect” setting. Discon-
nected
Solid
Red
ON
Average current >30A, current
disconnect. Auto reconnect after
10secs when FET temperature falls
below 70C and if voltage meets “pull-
in” spec. Disconnected
Table 5-1, LED Indicators
Summary of Contents for MagnaSine Smart Battery Combiner ME-SBC
Page 1: ...ME SBC TM Smart Battery CombinerTM Owner s Manual...
Page 9: ...2010 Enerdrive Pty Ltd 6 Installation Figure 2 5 ME SBC 25 Amp Combiner Mode...
Page 11: ...2010 Enerdrive Pty Ltd 8 Installation Figure 2 6 Solenoid Drive...
Page 13: ...2010 Enerdrive Pty Ltd 10 Installation Figure 2 7 Remote Volt Sense...