5
©2010 Enerdrive Pty Ltd
Installation
2.4.1 ME-SBC
TM
Wiring Connections - 25 Amp
CAUTION: Before connecting any wires, turn off any battery charger and
loads that are connected to the battery banks that the ME-SBC
TM
will be
combining.
Info: If installing in a boat, RV or truck, ensure the conductors passing
through walls, bulkheads or other structural members are protected to
minimize insulation damage such as chafing; which can be caused by
vibration or constant rubbing.
The ME-SBC
TM
should now be mounted if not please refer to section 2.2. During
installation please refer to Figures 2-5 during the following steps:
1. Unplug the Power Terminal Block from ME-SBC
TM
and ensure the openings
are unscrewed enough to allow the wires to be inserted.
2. Select and connect an appropriately sized red wire
1
from terminal #1 - MAIN
POS (+) on the Power Terminal Block to the positive terminal of the Main
Battery.
3. Select and Connect an appropriately sized red wire with a white stripe
1
from
terminal #2 - AUX POS (+) on the Power Terminal Block to the positive terminal
of the Auxiliary Battery.
4. Select and connect an appropriately sized a black wire
1
from terminal #3 -
COM NEG (-) on the Power Terminal Block to the Negative bus-bar or vehicle
chassis.
Info: The Negative busbar must connect the negative terminals on the
Main and Auxiliary Batteries together.
5. When all the connections are made and checked, plug the Power Terminal
Block into the ME-SBC
TM
to supply DC power.
Info: If there is a miswire in the system the “Reverse Polarity” LED will be
on. Correct the polarity of the wires connected to the Main Terminal.
6. Immediately after applying DC power, the LED’s on the ME-SBC
TM
should come
on as the unit goes through a power-up self-test. After the initial self-test com-
pletes, the Status LED should be illuminated. If so, your ME-SBC
TM
is now ready
for set-up; if not, please refer to the troubleshooting section.
note 1 : The wires connected to #1 - MAIN POS (+), #2 - AUX POS (+) and
#3 - COM NEG (-) should be sized for 30 amps and the same size. The battery
positive #1 - MAIN POS (+) and #2 - AUX POS (+) lines should be protected
with a 30 Amp fast blow fuse. Wire size should be appropriate for the application.
3 m
4.5 m
6 m
9 m
12 V
10 AWG
8 AWG
not recommended not recommended
24 V
12 AWG
12 AWG
10 AWG
8 AWG
Table 2-4, Recommended Wires Sizes for 3% loss
Summary of Contents for MagnaSine Smart Battery Combiner ME-SBC
Page 1: ...ME SBC TM Smart Battery CombinerTM Owner s Manual...
Page 9: ...2010 Enerdrive Pty Ltd 6 Installation Figure 2 5 ME SBC 25 Amp Combiner Mode...
Page 11: ...2010 Enerdrive Pty Ltd 8 Installation Figure 2 6 Solenoid Drive...
Page 13: ...2010 Enerdrive Pty Ltd 10 Installation Figure 2 7 Remote Volt Sense...