7.0 Specifications
15
©2010 Enerdrive Pty Ltd
Table 7-1, Specifications
Sense Module/Meter Specifications
DC Volts
12 or 24 VDC nominal
DC Amps
25 Amps Continuous;
Maximum VDC
40V peak
Average Operating Tare Loss
~150mW
Maximum Operatinng Tare Loss
<220mW
Non-operating Tare Loss
(on - not combined)
<50mWatts
Operating Range:
0-32 VDC
Shipping Weight:
~0.9kg. (Includes Manual)
Shipping Dimensions
254 x 203 x 76 mm
Unit Dimensions
107 x 127 x 36 mm
Maximum Operating
Temperature
-40 to 85C
Maximum Storage
Temperature
-40 to 90C
Regulatory
Ignition Protected