background image

©2010 Enerdrive Pty Ltd 

4

Installation

2.4 Configurations 

The ME-SBC

TM

 can be configured to accomplish battery combining in a simple, flex-

ible way. There are two methods and they are as follows: 

25 Amp Combiner - This configuration is simple to install and use. The 3-wire con-

nection system is similar to connection methods used by other battery combining 

products. One of the the advantages of this controller is the advanced combining 

options that are available to the installer. It is best to choose this method when 

designing systems where 25 amps or less are required.  For this configuration see 

Figure 2-5. 

Solenoid Drive - If more battery combining capacity (or Ampacity) is required the 

installer can employ any solenoid, so long as the coil of that solenoid consumes less 

than 2 Amps. The source that provides power to the solenoid must not exceed 40 

VDC. This circuit switches DC Negative to the accessory terminal block position #4 

entitled Solenoid (-). For this configuration please see Figure 2-6. 

Figure 2-2, Power Terminal Block

Figure 2-3, Accessories Terminal Block

2.3 Connections

Please refer to the diagrams below for connectivity information. 

Summary of Contents for MagnaSine Smart Battery Combiner ME-SBC

Page 1: ...ME SBC TM Smart Battery CombinerTM Owner s Manual...

Page 2: ...ty informa tion contained in this manual before installing or using this product WARNINGS All electrical work must be performed in accordance with local state and federal electrical codes This product...

Page 3: ...Figure 3 1 Battery Combining Setpoints 11 Figure 3 2 Battery Combining Operation 12 List of Sections 1 0 Introduction 1 2 0 Installation 3 3 0 Adjusting the ME SBCTM 11 4 0 Limitations of Throughput...

Page 4: ...points allowing different batteries to be charged from a single charging source and preventing over or under charging 1 1 Product Features Compatible with 12 or 24 volt Systems Very easy install and s...

Page 5: ...DISCONNECT settings for maximum charging flexibility 3 Reset Switch Performs a full reset of the ME SBCTM 4 Power Terminal Block The oversized removable terminal block allows fast and easy wire conne...

Page 6: ...formation on the front inside cover page before any installation 2 2 Location and Mounting Select a location that is dry and away from extreme temperatures to mount the ME SBCTM using the supplied 8 x...

Page 7: ...aller It is best to choose this method when designing systems where 25 amps or less are required For this configuration see Figure 2 5 Solenoid Drive If more battery combining capacity or Ampacity is...

Page 8: ...the Auxiliary Battery 4 Select and connect an appropriately sized a black wire1 from terminal 3 COM NEG on the Power Terminal Block to the Negative bus bar or vehicle chassis Info The Negative busbar...

Page 9: ...2010 Enerdrive Pty Ltd 6 Installation Figure 2 5 ME SBC 25 Amp Combiner Mode...

Page 10: ...The negative busbar must connect the negative terminals on the Main and Auxiliary Batteries together 5 Use an appropriately sized wire2 to connect each terminal of the solenoid to the appropriate batt...

Page 11: ...2010 Enerdrive Pty Ltd 8 Installation Figure 2 6 Solenoid Drive...

Page 12: ...egative and positive battery cables are discon nected from the battery bank Info If installing in a boat RV or truck ensure the conductors passing through walls bulkheads or other structural members a...

Page 13: ...2010 Enerdrive Pty Ltd 10 Installation Figure 2 7 Remote Volt Sense...

Page 14: ...12 8 13 8 VDC adjusts the point at which the ME SBCTM passes the charge from the Main Battery bank to the Auxiliary Battery bank or vice versa This setting is not active until a charging source is app...

Page 15: ...sdown to protect itself it will restart in 10 Seconds and attempt to recombine If the ME SBCTM reduces the output in order to maintain a stable output it will return to full output as soon as the aver...

Page 16: ...LVD Disconnected OFF Slow Blink High Voltage Disconnect HVD Disconnected Solid Green OFF FET switch connects MAIN and AUX connect voltage requirement is met on either battery connected Slow Blinking G...

Page 17: ...ect Remove the fuse at both batteries and check resistance at 1 MAIN POS and 2 AUX POS on the ME SBCTM There should be about 600k Ohms If there isn t the ME SBCTM might be defective Please call Enerdr...

Page 18: ...C 40V peak Average Operating Tare Loss 150mW Maximum Operatinng Tare Loss 220mW Non operating Tare Loss on not combined 50mWatts Operating Range 0 32 VDC Shipping Weight 0 9kg Includes Manual Shipping...

Page 19: ...e limited warranty shall be the actual cash value of the product at the time the original purchaser returns the product for repair determined by the price paid by the original purchaser Enerdrive shal...

Page 20: ...PN 64 0019 MagnaSine by Enerdrive Unit 11 1029 Manly Road Tingalpa Queensland Australia 4173 Ph 1300 851 535 email sales enerdrive com au www enerdrive com au...