Commissioning Instructions for PTB gas approval Proline Promass 84
Technical data
Hauser
23
6.1.5
Input
Measured variable
• Mass flow
(proportional to the phase difference between two sensors mounted on the measuring tube which
register a phase shift in the oscillation)
• Fluid density
(proportional to the resonance frequency of the measuring tube)
• Fluid temperature
(via temperature sensors)/(not suitable for custody transfer measurement)
Measuring range
Promass A
Promass F
Promass O
Promass X
DN
Minimum flow
Q
min
[kg/h]
Maximum flow
Q
max
[kg/h]
Lowest permitted density at
p
e,min
[kg/m
3
]
[mm]
[inch]
1
1/24
0.072
0.6
·
pe, min
2.4
2
1/12
0.360
2.3
·
pe, min
3.1
4
1/8
1.700
11
·
pe, min
3.1
pe, min
= density [kg/m
3
] at meter input at minimum operating overpressure P
e, min
DN
Minimum flow
Q
min
[kg/h]
Maximum flow
Q
max
[kg/h]
Lowest permitted density at
p
e,min
[kg/m
3
]
[mm]
[inch]
8
3/8
3.6
20 ·
pe, min
3.6
15
½
12.0
60
·
pe, min
4.0
25
1
30.0
200
·
pe, min
3.0
40
1½
135.0
400
·
pe, min
6.8
50
2
210.0
600
·
pe, min
7.0
80
3
550.0
1200
·
pe, min
9.2
100
4
1260.0
2000
·
pe, min
12.6
150
6
1860.0
3000
·
pe, min
12.4
250
10
5100.0
8000
·
pe, min
12.8
pe, min
= density [kg/m
3
] at meter input at minimum operating overpressure P
e, min
DN
Minimum flow
Q
min
[kg/h]
Maximum flow
Q
max
[kg/h]
Lowest permitted density at
p
e,min
[kg/m
3
]
[mm]
[inch]
80
3
550.0
1200
·
pe, min
9.2
100
4
1260.0
2000
·
pe, min
12.6
150
6
1860.0
3000
·
pe, min
12.4
250
10
5100.0
8000
·
pe, min
12.8
pe, min
= density [kg/m
3
] at meter input at minimum operating overpressure P
e, min
DN
Minimum flow
Q
min
[kg/h]
Maximum flow
Q
max
[kg/h]
Lowest permitted density at
p
e,min
[kg/m
3
]
[mm]
[inch]
350
14
10200.0
16000
·
pe, min
12.8
pe, min
= density [kg/m
3
] at meter input at minimum operating overpressure P
e, min