PROline Promag 23
10 Technical data
Hauser
99
Process connections with gasket seal (DN 40…100)
Weld nipples for DIN 11850 pipe
1.4404 / 316L
5*H**-U***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
L1
[mm]
LK
[mm]
40
38.0
43
92
42
19
71.0
50
50.0
55
105
42
19
83.5
65
66.0
72
121
42
21
100.0
80
81.0
87
147
42
24
121.0
100
100.0
106
168
42
24
141.5
– Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
– If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 89) and
process connection (di) into account.
F
06-x
x
Hx
x
x
x
x
-06-09-07-x
x
-002
Weld nipples for ODT pipe
1.4404 / 316L
5*H**-V***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
L1
[mm]
LK
[mm]
40
35.3
40
92
42
19
71.0
50
48.1
55
105
42
19
83.5
65
59.9
66
121
42
21
100.0
80
72.6
79
147
42
24
121.0
100
97.5
104
168
42
24
141.5
– Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
– If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 89) and
process connection (di) into account.
F06-x
x
Hx
x
x
x
x
-06-09
-0
7-x
x
-002
Clamp ISO 2852
1.4404 / 316L
5*H**-W***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40
35.6
50.5
92
68.5
71.0
50
48.6
64.0
105
68.5
83.5
65
60.3
77.5
121
68.5
100.0
80
72.9
91.0
147
68.5
121.0
100
97.6
119.0
168
68.5
141.5
– Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
– If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 89) and
process connection (di) into account.
F0
6-
x
x
H
x
x
x
x
x
-06-09-07-x
x
-005
Clamp DIN 32676
1.4404 / 316L
5*H**-0***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40
38
50.5
92
61.5
71.0
50
50
64.0
105
61.5
83.5
65
66
91.0
121
68.0
100.0
80
81
106.0
147
68.0
121.0
100
100
119.0
168
68.0
141.5
– Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
– If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 89) and
process connection (di) into account.
F
0
6
-x
x
Hxxxx
x-0
6
-0
9
-0
7
-xx-0
0
8
Summary of Contents for PROline promag 23
Page 4: ...Contents PROline Promag 23 4 Endress Hauser ...
Page 10: ...2 Identification PROline Promag 23 10 Endress Hauser ...
Page 30: ...3 Installation PROline Promag 23 30 Endress Hauser ...
Page 40: ...4 Wiring PROline Promag 23 40 Endress Hauser ...
Page 52: ...5 Operation PROline Promag 23 52 Endress Hauser ...
Page 56: ...6 Commissioning PROline Promag 23 56 Endress Hauser ...
Page 58: ...7 Maintenance PROline Promag 23 58 Endress Hauser ...
Page 102: ...10 Technical data PROline Promag 23 102 Endress Hauser ...