5 Operation
PROline Promag 23
42
Hauser
Display (operation mode)
The display area consists of three lines in all; this is where measured values are dis-
played, and/or status variables (direction of flow, partially filled pipe, bargraph, etc.).
You can change the assignment of display lines to variables at will in order to customize
the display to suit your needs and preferences (
see the “Description of Device
Functions” manual).
Error messages:
The display modes for system and process error messages are described in detail on
Page 45 ff.
Fig. 30:
Typical display for normal operating mode (HOME position)
1
Main line shows primary measured values, e.g. volume flow in [l/s].
2
Supplementary line shows supplementary measured variables and status variables, e.g. totalizer in [m
3
]
3
Information line shows additional information on the measured variables and status variables, e.g. bar
graph of the limit value achieved by the volume flow.
4
“Info icons” field: Icons representing additional information on the measured values are shown in this
field. See Page 42 for a full list of the icons and their meanings.
5
“Measured values” field: The current measured values appear in this field.
6
“Unit of measure” field: The units of measure and time defined for the current measured values appear
in this field.
Additional display functions
From HOME position, use the +/- keys to open an “Info Menu” containing the following
information:
Totalizers (including overflow)
Actual values or states of the configured outputs
Device TAG number (user-definable)
P
Scan of individual values within the Info Menu
X
(Esc key)
Back to HOME position
Icons
The icons which appear in the field on the left make it easier to read and recognize
error messages.
Icon
Meaning
S
System error
P
Process error
Fault message (with effect on outputs)
!
Notice message (without effect on outputs)
1
4
5
6
2
3
+24.502
+1863.97
l
m
3
s
–50
+50
F
06-23x
x
x
x
x
x
-0
7
-x
x
-x
x
-x
x
-001
Summary of Contents for PROline promag 23
Page 4: ...Contents PROline Promag 23 4 Endress Hauser ...
Page 10: ...2 Identification PROline Promag 23 10 Endress Hauser ...
Page 30: ...3 Installation PROline Promag 23 30 Endress Hauser ...
Page 40: ...4 Wiring PROline Promag 23 40 Endress Hauser ...
Page 52: ...5 Operation PROline Promag 23 52 Endress Hauser ...
Page 56: ...6 Commissioning PROline Promag 23 56 Endress Hauser ...
Page 58: ...7 Maintenance PROline Promag 23 58 Endress Hauser ...
Page 102: ...10 Technical data PROline Promag 23 102 Endress Hauser ...