PROline Promag 23
3 Installation
Hauser
19
Promag H
Flow rate characteristic values - Promag H (SI units)
Nominal
diameter
Recommended
flow rate
Factory settings
[mm]
inch]
min./max. full scale value
(v ~ 0.3 or 10 m/s)
Full scale value
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
2
1/12"
0.06…1.8
dm
3
/min
0.5
dm
3
/min
0.005
dm
3
0.01
dm
3
/min
4
5/32"
0.25…7
dm
3
/min
2
dm
3
/min
0.025
dm
3
0.05
dm
3
/min
8
5/16"
1…30
dm
3
/min
8
dm
3
/min
0.10
dm
3
0.1
dm
3
/min
15
1/2"
4…100
dm
3
/min
25
dm
3
/min
0.20
dm
3
0.5
dm
3
/min
25
1"
9…300
dm
3
/min
75
dm
3
/min
0.50
dm
3
1
dm
3
/min
40
1 1/2"
25…700
dm
3
/min
200
dm
3
/min
1.50
dm
3
3
dm
3
/min
50
2"
35…1100
dm
3
/min
300
dm
3
/min
2.50
dm
3
5
dm
3
/min
65
2 1/2"
60…2000
dm
3
/min
500
dm
3
/min
5.00
dm
3
8
dm
3
/min
80
3"
90…3000
dm
3
/min
750
dm
3
/min
5.00
dm
3
12
dm
3
/min
100
4"
145…4700
dm
3
/min
1200
dm
3
/min
10.00
dm
3
20
dm
3
/min
Flow rate characteristic values - Promag H (US units)
Nominal diameter
Recommended
flow rate
Factory settings
[inch]
[mm]
min./max. full scale value
(v ~ 0.3 or 10 m/s)
Full scale value
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
1/12"
2
0.015…0.5
gal/min
0.1
gal/min
0.001
gal
0.002
gal/min
5/32"
4
0.07…2
gal/min
0.5
gal/min
0.005
gal
0.008
gal/min
5/16"
8
0.25…8
gal/min
2
gal/min
0.02
gal
0.025
gal/min
1/2"
15
1.0…27
gal/min
6
gal/min
0.05
gal
0.10
gal/min
1"
22
2.5…65
gal/min
18
gal/min
0.20
gal
0.25
gal/min
1 1/2"
40
7…190
gal/min
50
gal/min
0.50
gal
0.75
gal/min
2"
50
10…300
gal/min
75
gal/min
0.50
gal
1.25
gal/min
2 1/2"
65
16…500
gal/min
130
gal/min
1
gal
2.0
gal/min
3"
80
24…800
gal/min
200
gal/min
2
gal
2.5
gal/min
4"
100
40…1250
gal/min
300
gal/min
2
gal
4.0
gal/min
Summary of Contents for PROline promag 23
Page 4: ...Contents PROline Promag 23 4 Endress Hauser ...
Page 10: ...2 Identification PROline Promag 23 10 Endress Hauser ...
Page 30: ...3 Installation PROline Promag 23 30 Endress Hauser ...
Page 40: ...4 Wiring PROline Promag 23 40 Endress Hauser ...
Page 52: ...5 Operation PROline Promag 23 52 Endress Hauser ...
Page 56: ...6 Commissioning PROline Promag 23 56 Endress Hauser ...
Page 58: ...7 Maintenance PROline Promag 23 58 Endress Hauser ...
Page 102: ...10 Technical data PROline Promag 23 102 Endress Hauser ...