Operation
Deltabar S FMD77, FMD78, PMD75 with FOUNDATION Fieldbus
48
Hauser
Display Transducer Block
Diagnostic Transducer Block
INPUT_PRESSURE_INVERSION
Inp.press invers
53
Unsigned8
1
S
x
x
)
OOS
1)
Can be written with service code
Parameter name,
option "Symbolic name"
Parameter name,
option "Label"
Index Data type
Size
(Byte)
Storage
Class
Read
Writ
e
MODE_BLK
Reset codes
Parameter name,
option "Symbolic name"
Parameter name,
option "Label"
Index Data type
Size
(Byte)
Storage
Class
Read
Writ
e
BLK_MODE
Reset codes
DEVICE_DIALOG
Device dialog
10
Unsigned8
1
D
x
DISPLAY_MAINLINE_CONTENT
Main line cont.
11
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
DISPLAY_MAINLINE_FORMAT
Main data format
12
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
DISPLAY_ALTERNATING_VALUES
Alternate data
13
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
DISPLAY_CONTRAST
Display contrast
14
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
DISPLAY_LANGUAGE
Language
15
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
SIL_DIGITS_TEST_STRING
Digits set
16
Visible String 16
D
x
Parameter name,
option "Symbolic name"
Parameter name,
option "Label"
Index Data type
Size
(Byte)
Storage
Class
Read
Writ
e
BLK_MODE
Reset codes
DEVICE_DIALOG
Device dialog
10
Unsigned8
1
D
x
SW_LOCK
Insert PIN no.
11
Unsigned16
2
S
x
x
AUTO, OOS,
MAN
7864, 333
STATUS_LOCKING
Status locking
12
Unsigned16
2
D
x
SIMULATION_MODE
Simulation mode
13
Unsigned8
1
D
x
x
OOS
SCALE_OUT_UNITS_INDEX
Units index
14
Unsigned16
2
S
x
SIMULATED_VALUE
Simulated value
15
Float
4
D
x
x
AUTO, OOS,
MAN
SIMULATION_ERROR_NUMBER
Sim. error no.
16
Unsigned16
2
D
x
x
AUTO, OOS,
MAN
ALARM_STATUS
-
17
Unsigned16
2
D
x
ALARM_STATUS_WITH_CATEGORY
Alarm status info
18
Unsigned16
2
D
x
LAST_DIAGNOSTIC_CODE
-
19
Unsigned16
2
D
x
LAST_DIAGNOSTIC_CODE_WITH_CATE
GORY
Last diag. code info
20
Unsigned16
2
D
x
ACKNOWLEDGE_ALARM_MODE
Ack. alarm mode
21
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
ACKNOWLEDGE_ALARM
Ack. alarm
22
Unsigned8
1
D
x
x
AUTO, OOS,
MAN
RESET_ALL_ALARMS
Reset all alarms
23
Unsigned8
1
D
x
x
AUTO, OOS,
MAN
ERROR_NUMBER
Error no.
24
Unsigned16
2
D
x
x
AUTO, OOS,
MAN
SELECT_ALARM_TYPE
Select alarm type
25
Unsigned8
1
D
x
x
AUTO, OOS,
MAN
ALARM_DELAY
Alarm delay
26
Float
4
S
x
x
AUTO, OOS,
MAN
7864
ALARM_DISPLAY_TIME
Alarm displ. time
27
Float
4
S
x
x
AUTO, OOS,
MAN
7864
PRESSURE_UNIT
Cal. unit
28
Unsigned16
2
S
x
7864, 333
PMIN_ALARM_WINDOW
Pmin alarm window
29
Float
4
S
x
x
AUTO, OOS,
MAN
7864
PMAX_ALARM_WINDOW
Pmax alarm window
30
Float
4
S
x
x
AUTO, OOS,
MAN
7864
TEMPERATURE_UNIT
Temp. eng. unit
31
Unsigned16
2
S
x
7864,
333
TMIN_ALARM_WINDOW
Tmin. alarm window
32
Float
4
S
x
x
AUTO, OOS,
MAN
7864
TMAX_ALARM_WINDOW
Tmax. alarm window
33
Float
4
S
x
x
AUTO, OOS,
MAN
7864
ENTER_RESET_CODE
Enter reset code
34
Unsigned16
2
D
x
x
AUTO, OOS,
MAN
OPERATING_HOURS
Operating hours
35
Unsigned32
4
D
x
STATUS_HISTORY
Alarm history
36
Visible String 18
D
x
HIGHEST_CATEGORY
-
37
Unsigned8
1
D
x