39357-0-1018
Page 91
110 VOLT AC
JUNCTION BOX
WHITE
SPEED
CONTROL
FAN
SWITCH
GROUND
BLACK
FAN
1
R7731 BLOWER MOTOR
2
31920
SWITCH ASSEMBLY
3
R4192 SPEED CONTROL kNOB
4
R4186 SPEED CONTROL
FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
Figure 96
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
to the receptacle that is provided. Leave approximately 6" of wire
in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
CAUTION
All wiring should be done by a qualified electrician and shall
be in compliance with all local, city and state building codes.
Before making the electrical connection, make sure that main
power supply is disconnected. The appliance, when installed,
must be electrically grounded in accordance with local codes
or, in the absence of local codes, with the national electrical
code ansi/nfpa 70 (latest edition).
Summary of Contents for MILLIVOLT STANDING PILOT DVX36FP31L-4
Page 52: ...39357 0 1018 Page 52 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Page 54: ...39357 0 1018 Page 54 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Page 57: ...39357 0 1018 Page 57 LOG PLACEMENT 17 The log assembly is now complete...