39357-0-1018
Page 67
GAS SHUT-OFF VALVE
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Remove front surround panel assembly or bottom louver if
included.
4. Turn gas shut-off counterclockwise
to “On” position.
5. Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow “B” in
the safety information above on this page. If you do not smell
gas, go to the next step.
6. Turn ON electric power to the appliance.
7. Find pilot - Follow metal tube from gas control. The pilot is
behind the burner on the right side.
8. Turn main flame to on. If the pilot does not light within 60
seconds, stop and go to Step 5.
9. Refer to remote control instructions for detailed information,
control features, and operation. Note: There is a CPI/IPI
switch that allows for a continuous standing pilot mode or an
intermittent pilot mode. See appliance manual for location
of this switch. If the pilot or burner does not stay lit (in the
standing pilot mode), stop and immediately call a qualified
service technician or gas supplier.
10. If the burner or pilot does not operate properly after several
tries, turn the gas shut-off clockwise
to “OFF” and
call your service technician or gas supplier.
11. Replace the front surround assembly or close bottom louver
assembly.
12. Operation of the gas valve is controlled by a manual on/
off switch or a hand held remote control. Refer to remote
instructions for detailed operation information.
INTERMITTENT PILOT LIGHTING INSTRUCTIONS
A. This appliance has a pilot which can be lighted with the
manual on/off switch, a remote control, or by switching the
receiver switch to the “ON” position. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical
switch. Do not use any phone in your building. Immediately
call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions. If you can not reach your gas
supplier, call the fire department.
C. Use only the remote control or manual remote receiver
switch to operate the gas valve. Never use tools. If valve
does not operate, don’t try to repair it, call a qualified ser
-
vice technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
1. Turn off all electric power to the appliance if service is to be
performed (if applicable).
2. Gain access to control compart. Remove surround panel
assembly if necessary.
3. Locate On/Off gas shut-off and turn clockwise to
“OFF”. Do not force.
4. Close bottom louver assembly, if included.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
Summary of Contents for MILLIVOLT STANDING PILOT DVX36FP31L-4
Page 52: ...39357 0 1018 Page 52 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Page 54: ...39357 0 1018 Page 54 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Page 57: ...39357 0 1018 Page 57 LOG PLACEMENT 17 The log assembly is now complete...