31453-6-0914
Page 20
Figure 26
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE
WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW
OFF TOP OF FIREPLACE
FIREPLACE
SERIES
HARD ELBOW DIMENSIONS
"A"
"B"
"C"
DVX36FP
43-1/2"
(1105 mm)
5"
(127 mm)
7"
(178 mm)
DVX42FP
43-1/2"
(1105 mm)
5"
(127 mm)
7"
(178 mm)
FIREPLACE
SERIES
FLEX PIPE 90 DEGREE BEND
"A"
"B"
"C"
DVX36FP
46"
(1143 mm)
5"
(127 mm)
7"
(178 mm)
DVX42FP
46"
(1143 mm)
5"
(127 mm)
7"
(178 mm)
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 12” (305 mm) high x 10” (254 mm) wide with its center line
determined by the amount of vertical rise and horizontal run of the
termination.
See Figure 26.
When locating the hole it must be noted
that the bottom of the cap must be 12” (305 mm) above the ground
level, and top of the cap must be no less than 18” (457 mm) below
a combustible projection, and no closer than 9” (229 mm) to any
wall running parallel to vent termination.
See Figure 27.
Figure 27
Figure 28
VENTING FIREPLACE - TOP (continued)
Summary of Contents for DVX36DP31N-3
Page 21: ...31453 6 0914 Page 21 Figure 31 Figure 29 Figure 30 EXAMPLES TOP VENT RUN ...
Page 35: ...31453 6 0914 Page 35 DVVK 4FV DIRECT VENT TERMINATION KIT cont Figure 54 ...
Page 49: ...31453 6 0914 Page 49 Figure 71 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM ...
Page 72: ...31453 6 0914 Page 72 PARTS VIEW Note Refer to page 46 when ordering logs ...