31453-6-0914
Page 7
Remote Control Options
& Accessories
Description
FRBC
Millivolt/IP Battery Remote ON/OFF
FRBTC
Millivolt/IP Battery Remote Thermostat
TRW
Millivolt/IP WIRELESS Wall Thermostat
TMV
Millivolt/IP REED SWITCH Wall Thermostat
FWS-1
Direct Ignition/Millivolt/IP Wall Switch
FREC
Electric Remote
SPECIFICATIONS
DVX36 NAT
DVX36 LP
DVX42 NAT
DVX42 LP
Input Btu/hr Maximum
35,000
30,000
37,500
35,000
Btu/hr Minimum
24,500
21,000
26,000
28,000
KWH (Maximum)
10.3
8.8
11
10.3
(Minimum)
7.2
6.2
7.6
7.2
Orifice - MV, IP, RF
#32 (P211)
1.65 mm (P250)
#31 (P209)
#50 (P245)
Orifice - DI
2.75mm (P305)
1.65 mm (P250)
2.75 mm (P305)
1.80mm (P304)
Air Shutter Opening
1/4”(6.4 mm)
FULL OPEN
1/4” (6.4 mm)
FULL OPEN
Height without standoff
34 3/4 (883 mm)
34 3/4” (883 mm)
34 3/4” (883 mm)
34 3/4” (883 mm)
Width
39 3/8” (1,000 mm)
39 3/8” (1,000 mm)
43 3/8” (1,101 mm)
43 3/8” (1,101 mm)
Depth
19 7/8” (505 mm)
19 7/8” (505 mm)
19 7/8” (505 mm)
19 7/8” (505 mm)
Gas Inlet Shutoff Valve (Pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
NOTICE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
The following vent systems are acceptable for use with the
DVX42 series fireplaces:
Simpson Duravent® GS 5” - 8”
American Metal Products 5” - 8”
Selkirk Direct-Temp® 5” - 8”
Security Secure Vent® 5” - 8”
Excel DV Venting 5” - 8”
Empire Flexvent Kit DVVK-5F
BDM 5” - 8”
SPECIAL VENT SYSTEMS
The following vent systems are acceptable for use with the
DVX36 series fireplaces:
Simpson Duravent® GS 4” - 6 ⅝”
American Metal Products 4” - 6 ⅝”
Selkirk Direct-Temp® 4” - 6 ⅝”
Security Secure Vent® 4” - 6 ⅝”
Excel DV Venting 4” - 6 ⅝”
BDM 4” - 6 ⅝”
Empire Horizontal Round Termination Kit DVVK-4RE
Note: DVA-47 not for use with Flex Vent Kits. For use with
Simpson Duravent vents only.
Summary of Contents for DVX36DP31N-3
Page 21: ...31453 6 0914 Page 21 Figure 31 Figure 29 Figure 30 EXAMPLES TOP VENT RUN ...
Page 35: ...31453 6 0914 Page 35 DVVK 4FV DIRECT VENT TERMINATION KIT cont Figure 54 ...
Page 49: ...31453 6 0914 Page 49 Figure 71 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM ...
Page 72: ...31453 6 0914 Page 72 PARTS VIEW Note Refer to page 46 when ordering logs ...