29209-0-0911
Page 20
Optional Wall Switch
Position the wall switch in the desired position on a wall. Run a
maximum of 25 feet (7.8m) or less length of 18 A.W.G. minimum
wire and connect it to the fireplace valve pigtails.
WARNING
DO NOT CONNECT THE 110-120 VAC TO THE WALL SWITCH
OR THE CONTROL VALVE WILL BE DESTROYED.
WARNING
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROL. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
For Standing Pilot Ignition Wiring
Appliance Requirements
WARNING
DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL
VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED.
STANDING PILOT WIRING
REMOTE/OFF/ON SWITCH
THERMOPILE
GAS VALVE
THERMOCOUPLE
OFF
ON
REMOTE
(OPTIONAL) WALL SWITCH
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
WIRING DIAGRAM
H
N
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.
RED
GREEN
BLACK
GREEN
REMOTE CONTROL RECEIVER
GAS VALVE
REMOTE/OFF/ON SWITCH
(OPTIONAL) REMOTE CONTROL RECEIVER
STANDING PILOT WIRING DIAGRAM