29209-0-0911
Page 14
ALTERNATE ON/OFF SWITCH INSTALLATION
WIRING THE FIREPLACE
NOTICE
: Electrical wiring must be installed by a licensed
electrician.
CAUTION
DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT
FOR EXTENDED TIME PERIODS. THIS WILL PREVENT AC-
CIDENTAL FIREPLACE OPERATION.
Installation of Alternate Surround Panel ON/OFF Switch
An ON/OFF switch and wire assembly are provided. They are in-
cluded in the instruction packet.
Do not cut wire or insulation on metal edges.
NOTICE
: Refer to surround panel installation section on page
15 for additional information on attachment.
Contemporary Surrounds
1. Find the coiled low voltage wire assembly and ON/OFF switch
located in the instruction packet.
2a. Millivolt Units:
Attach the flag terminal ends to the “TH/TP”
and “TH” terminals on the front terminal block of the gas valve.
See Figure 13.
2b. IP Units:
Disconnect the (2) black wires from the green
and white wire connectors. Connect alternate On/Off switch
wires to the green and white wires as shown in Figure 13b.
Note:
This bypasses the On/Off switch located on the unit’s
left hand side flange.
3. Run the low voltage alternate switch wires over to the right
or left surround panel. Then secure the wires with wire clips
provided.
See Figure 12.
Right Side Installation
Left Side Installation
ON/OFF
SWITCH
ASSEMBLY
ON/OFF
SWITCH
ASSEMBLY
WIRING FROM
MILLIVOLT GAS
VALVE
Figure 12
Insert ON/OFF switch into side panel then attach wire assem
-
bly from valve terminals.
4. Remove the switch knockout on the side surround panel, then
install the ON/OFF switch. See Figure 11.
5. Connect the low voltage wires from the gas valve to the
ON/OFF switch.
6. Attach the surround panel assembly to the insert. Hang the
surround panel assembly on the face of the insert and center
left to right. Swing the surround panel assembly inward until
the bottom magnets contact the insert body side flanges. This
secures the surround panel assembly to the insert without
screws.
Figure 13a
WHITE
WIRE
GREEN
WIRE
ALTERNATE ON/OFF SWITCH
(MOUNT IN LOWER LEFT CORNER
OF THE SURROUND PANEL)
DFC
ELECTRONIC
CONTROL
MODULE
NOTE: OTHER WIRING NOT SHOWN
FOR CLARITY PURPOSES ONLY
Figure 13b