background image

29209-0-0911

Page 5

Instructions to Installer

1.  Leave instruction manual with owner after installation.

2.  Have owner fill out and mail registration card supplied with the 

fireplace.

3.  Show owner how to start and operate the fireplace.

This direct-vent gas fireplace heater is designed to operate with 

all combustion air being siphoned from the outside of the building 

and all exhaust gases expelled to the outside of the building. The 

information contained in this manual pertains to all models and gas 

control systems unless otherwise noted.

 

WARNING

This unit is not for use with solid fuels

Appliance Certification 

This  fireplace  is  design  certified  in  accordance  with  American 

National Standard/CSA Standard ANSI Z.21-88/CSA 2.33 and by 

Underwriters Laboratories as a Direct Vent Gas Fireplace Heater 

and shall be installed according to these instructions.
Consult your local building code agency, prior to installation, to ensure 

compliance with local codes-including permits and inspections.

The fireplace insert, when installed, must be electrically grounded in 

accordance with local codes or, in absence of local codes, with the 

National Electric Code ANSI/NFPA 70

 or Canadian Electric code, 

CSA C22.1, if an external electrical source is utilized.
These models may be installed in a bedroom or bed-sitting room 

in the U.S.A. and Canada.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment 

or  accessories  and  repair  and  servicing  of  equipment  shall  be 

performed only by a qualified agency. The term “qualified agency” 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible for 

(a) the installation or replacement of gas piping or (b) the connection, 

installation, repair or servicing of equipment, who is experienced in 

such work, familiar with all precautions required and has complied 

with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by 

a licensed plumber or gas fitter in the Commonwealth of 

Massachusetts.

The installation must conform with local codes or, in the absence of 

local codes, with the 

National Fuel Gas Code ANSI Z223.1/NFPA 

54* Natural Gas and Propane Installation Code, or CSA B149.1 in 
Canada. *Available from the American National Standards Institute, 
Inc. 11 West 42nd St., New York, N.Y. 10036.

NOTICE:  Prior  to  operating  this  unit,  be  sure  to  clean  the 

interior porcelain coated liner panels and glass door with a 

soft  clean  cloth.  Due  to  normal  manufacturing  processes, 

 

fingerprints and excess sealing materials may be present and 

should be removed. When cleaning, do not use abrasives. 

Any alteration of the original design, installed other than as 

shown  in  these  instructions  or  use  with  a  type  of  gas  not 

shown on the rating plate is the responsibility of the person 

and company making the change.

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

High Altitude 

When installing this unit at an elevation above 2000 feet (in the 

United States) it may be necessary to decrease the input rating by 

changing the existing burner orifice to a smaller size. Generally, 

input should be reduced 4 percent for each 1000 feet above sea 

level. However, if the heating value of the gas has been reduced, 

this general rule may not apply. Check with local gas utility for proper 

orifice size identification.

Canadian High Altitude 

Altitude: 0-4500 feet (0-1370 m)
When installing this unit at an elevation above 4500 feet (in Canada), 

check with local authorities.
Consult your local gas utility for assistance in determining the proper 

orifice for location.

Preparation

This direct vent gas fireplace insert and its components are tested 

and safe when installed in accordance with this Installation Manual. 

Report to your dealer any parts damaged in shipment, specifically 

check glass condition. Do not install unit with damaged, incomplete, 

or substitute parts. Read all instructions before starting installation 

and follow these instructions carefully during installation to insure 

maximum benefit and safety. Failure to follow them will void your 

warranty and may present a fire hazard.

The warranty will be voided by, and the warranter disclaims any 

responsibility for the following actions:

•  Installation  of  any  damaged  fireplace  insert  or  vent  system 

component.

•  Modification of the fireplace insert or direct vent system.

•  Installation other than as instructed by Empire Comfort Systems, 

Inc.

•  Improper positioning of the optional decorative glass or glass 

door assembly.

•  Installation and/or use of any component part not manufactured 

or approved by manufacturer.

INTRODUCTION

 

WARNING

ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS 

CAN BE DANGEROUS.

Improper  installation  or  use  of  the  fireplace  can  cause 

serious  injury  or  death  from  fire,  burns,  explosions,  or 

carbon monoxide poisoning

Summary of Contents for DVL25IN33N-1

Page 1: ...NG If the information in these instruc tions are not followed exactly a fire or explo sion may result causing property damage personal injury or loss of life WARNING HOT GLASS DO NOT TOUCH NEVER WILL...

Page 2: ...y Information 16 Glass Placement 17 Operating Instructions 18 Standing Pilot Lighting Instructions 19 Standing Pilot Wiring 20 Standing Pilot Troubleshooting 21 IPI Electronic System Operating Instruc...

Page 3: ...ass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control compartment clean...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...West 42nd St New York N Y 10036 NOTICE Prior to operating this unit be sure to clean the interior porcelain coated liner panels and glass door with a soft clean cloth Due to normal manufacturing proc...

Page 6: ...s and clamps Recommended when installing to a square or rectangular clay flue DVK35 Vent Extension Kit 35 flex vent extension section with 2 connectors and 4 clamps NOTICE When installing vent caps sp...

Page 7: ...EPLACE INSERT DIMENSIONS all dimensions in inches MODEL A B C D E F G H I J K L M N O DVL25IN 28 16 1 2 15 10 1 2 25 1 4 12 3 4 17 18 5 16 27 6 7 8 9 1 4 20 22 1 4 40 22 1 2 DVL33IN 31 19 1 2 16 1 2 1...

Page 8: ...ation of any type should be placed on or attached to the fireplace The flow of heat can ignite combustibles Figure 4 8 MINIMUM CLEARANCE TO PERPENDICULAR COMBUSTIBLE SIDE WALL FROM EDGE OF DOOR FRAME...

Page 9: ...ne of the procedures results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the fireplace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural g...

Page 10: ...urround panel kits have been tested and approved to cover existing air circulation vents or grills NOTICE Cutting of sheet metal parts of a fireplace in order to install the fireplace insert is prohib...

Page 11: ...y chimney may need to be removed to allow installation of the flexible vent pipe When installing into a zero clearance factory built wood burning fireplace the use of the DVKI Round Vertical Terminati...

Page 12: ...CESS COVER PLATE BLOWER POWER CORD OPTIONAL ON OFF SWITCH LOCATION VENT CLAMPS RECTANGULAR TERMINATION CAP DVVK3FV KIT ROUND TERMINATION CAP DVKI KIT ROUND CO LINEAR TO CO AXIAL ADAPTOR 10 MINIMUM 35...

Page 13: ...stem exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such as wall straps or plumbers t...

Page 14: ...d white wires as shown in Figure 13b Note This bypasses the On Off switch located on the unit s left hand side flange 3 Run the low voltage alternate switch wires over to the right or left surround pa...

Page 15: ...THE FIREPLACE INSERT NEVER OB STRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE INSERT IN ANY MANNER SURROUND ASSEMBLY ENGAGE SIDE PANEL MAGNETS TO SIDE FLANGES ON INSERT BACK SIDE NOTE...

Page 16: ...oval of the blower system must be performed by a qualified service person If the blower assembly must be replaced the following steps are recommended for removal 1 Turn off gas and disconnect the elec...

Page 17: ...Glass should only be performed after the DVL Fireplace Insert has been fully installed secured and tested for leaks If operating the burner with a Remote Control make sure all batteries are installed...

Page 18: ...ilot The pilot remains ON even when the main burner is OFF Whenyouignitethepilot thethermopileproducesmillivolts electrical current which energizes the magnet in the gas valve After 30 seconds to 1 mi...

Page 19: ...applicable 13 Set REMOTE OFF ON switch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property...

Page 20: ...PERATION AFTER SERVICING For Standing Pilot Ignition Wiring Appliance Requirements WARNING DO NOT CONNECT 110 120 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE D...

Page 21: ...t bracket Check the thermopile with a millivolt meter Take the reading at TH TP TP terminals of the gas valve The metershouldread350millivoltsminimum whileholdingthe valve knob depressed in the PILOT...

Page 22: ...and LIGHTING INSTRUCTIONS for In termittent Pilot controls found in this manual and on labels found in the control compartment located in the lower cavity of the appliance 2 During the operating seaso...

Page 23: ...t is used CAUTION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation...

Page 24: ...structions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage person...

Page 25: ...ions on page 24 and Wiring Diagram on page 23 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and th...

Page 26: ...ire harness 4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 I...

Page 27: ...and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at...

Page 28: ...g Glass Door Frequency After the first 3 to 4 hours of use As necessary after initial cleaning By Home owner Task Remove and clean glass after the first 3 to 4 hours of use After the initial cleaning...

Page 29: ...L25IN 43 DVL33IN 22 1 4 DVL25IN 25 1 4 DVL33IN 6 2 1 4 6 28 DVL25IN 31 DVL33IN 14 DVL25IN 17 DVL33IN Black Used to raise insert and surround panels when installed in a fireplace without a flush hearth...

Page 30: ...3 N P 1 22950 22950 22950 22950 FLUE CONNECTOR GUIDE 2 23309 23211 23309 23211 SLIDE PLATE ASSEMBLY 3 R9188 R9188 R9188 R9188 GASKET TOP 4 16223 27718 16223 27718 SPRING RETAINER ASSEMBLY 5 27666 2769...

Page 31: ...5 28063 28063 28683 28683 VALVE BRACKET 26a R7577 R7577 R11125 R11125 VALVE SIT NAT 26b R7578 R7578 R11126 R11126 VALVE SIT LP 27 R6207 R6207 R6207 R6207 ELBOW 5 16 X 3 8 NPT 90 28 27147 27672 28791 2...

Page 32: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 33: ...29209 0 0911 Page 33 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 34: ...29209 0 0911 Page 34 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 35: ...29209 0 0911 Page 35 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 36: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: