5. UNITS POSITIONING
5. UNITS POSITIONING
5.3 Minimum operational
distances of indoor unit
5.4 Minimum operational
distances of outdoor unit
A
D
E
C
B
The two air conditioner units are connected to each other by means
of copper piping. A maximum of 10 curves is allowed and beyond this
number the correct operation and the declared yield of the air conditioner
are not guaranteed.
The two units can be positioned with a maximum gradient of 5 metres.
In cases where the indoor unit is installed higher than the outdoor unit
with: Between 3 and 5 meters must be provided an intermediate siphon
to lock oil.
Warning!
Both pipe-lines must be provided with siphon.
1/2
1/2
A (mm)
B (mm)
C (mm)
D (mm)
150
150
2500
3000
A
B
C
D
E
300
500
300
2000
500
5.5 Distance between the units
UNIT
Difference
maximum
between
UI e UE
Difference
minimum
between
UI e UE
Charge
Additional
than 5 m
m
m
g/m
XECO-0913
10
15
20
XECO-1213
10
20
20
XECO-1813
10
25
20
XECO-2413
10
25
20
XECO-1813D
10
20
15
XECO-2413T
10
20
15