background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

DTXF25T2VMA

DTXF50T2VMA

DTXF35T2VMA

Summary of Contents for DTXF25T2VMA

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS DTXF25T2VMA DTXF50T2VMA DTXF35T2VMA...

Page 2: ...hanges to energy saving operation Page 14 OUTDOOR UNIT QUIET OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit This function is useful when you need to consider the noise for you...

Page 3: ...ration 20 ON TIMER Operation 21 OUTDOOR UNIT QUIET Operation 2 Contents Read before Operation Safety Precautions 3 Name of Parts 5 Preparation before Operation 8 Operation Care Care and Cleaning 22 Tr...

Page 4: ...nt other than the one indicated on the outdoor unit R32 when installing moving or repairing Using other refrigerants may cause trouble or damage to the unit and personal injury To avoid electric shock...

Page 5: ...t Leaves are a hotbed for small animals which can enter the unit Once inside the unit such animals can cause malfunctions smoke or if they come into contact with electrical parts Do not place objects...

Page 6: ...ng operation Display ON OFF Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Operation start beep beep Settings changed beep Op...

Page 7: ...et Air inlet back and side Refrigerant piping and inter unit wiring Model name plate Earth terminal inside Drain hose Outdoor temperature sensor back Air outlet Air inlet back and side Outdoor tempera...

Page 8: ...ction is shown with its displays on for the purpose of explanation TEMPERATURE adjustment buttons It changes the temperature setting Page 10 OFF button Press this button to stop operation Page 9 POWER...

Page 9: ...atteries off The batteries will last for approx 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries...

Page 10: ...t is recommended to use another heating appliance in r The heat pump system heats the room by circulating hot air around all parts of the room After the start of HEAT operation it takes some time befo...

Page 11: ...Notes on the operating conditions The air conditioner always consumes a small amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for...

Page 12: ...flaps If you attempt to move the flaps forcibly by hand when they are swinging the mechanism may be broken Hold the knob and move the louvers You will find a knob on the left side and the right side...

Page 13: ...indoor unit quiet ope When the airflow is set to ration will start and the noise from the unit will become quiete In indoor unit quiet operation the airflow rate is set to a weak level If the temperat...

Page 14: ...n from before COMFORT AIRFLOW operation The flap position will change preventing air from blowing directly on the occupants of the room POWERFUL operation and COMFORT AIRFLOW operation cannot be used...

Page 15: ...temperature 2 0 C in HEAT 2 0 C in COOL 2 0 C in DRY operation from set temperature When the room temperature exceeds 30 0 C the operation changes the temperature 1 0 C in COOL 1 0 C in DRY operation...

Page 16: ...ending on the clothes the people are wearing if there are no movements of the people in the area Due to the position of the sensor people might be exposed to the airflow of the indoor unit if they are...

Page 17: ...ECONO or OUTDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing causes the settings to...

Page 18: ...breaker may trip if the air conditioner operate with its maximum capacity The maximum power consumption of the air conditioner is limited by using ECONO operation The circuit breaker will hardly trip...

Page 19: ...CONO operation is a function which enables efficient operation by limiting the power consumption of the outdoor unit operating frequency ration functions in AUTO COOL DRY and HEAT operation POWERFUL a...

Page 20: ...FAN ONLY and DRY operation POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time Priority is given to the function of whichever button is pressed last Even the operation...

Page 21: ...by 1 hour The TIMER lamp lights Setting time can be increase to 12 hours maximum orange To cancel OFF TIMER operation Press The TIMER lamp goes off NOTE Notes on TIMER operation When operating the un...

Page 22: ...amp goes off To combine ON TIMER and OFF TIMER A sample setting When setting while unit is operating for combining the 2 timers is shown below Example Turn off unit in the next 1 hr Turn on unit in th...

Page 23: ...l detergent may be used If dirty Page 23 Table 1 BAFP094A43 BAFP094A41 BAFP046A41 KAF970A46 Cleaning Replacement Once every 6 months Once every 3 years Page 25 Page 25 Page 25 To purchase the filters...

Page 24: ...ward you This will disconnect the front panel shaft on one side Disconnect the front panel shaft on the other side in the same manner Clean the front panel 2 Wipe it lightly with a soft cloth soaked i...

Page 25: ...f each air filter then pull it down Wash the air filters with 2 water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks Air filter If the dust does not come of...

Page 26: ...t panel at both sides and the center This lter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the lter when removing wat...

Page 27: ...art Fan only operation 2 After operation stops turn off the breaker for the room air conditioner 3 4 Take out batteries f Clean the air filters and set them again Operate the FAN only for several hour...

Page 28: ...r and heard when the water is pumped out from the air conditioner in cooling or drying operation The refrigerant ows in the air conditioner even if the air conditioner is not working when the indoor u...

Page 29: ...h t e r A approp Are the airflow rate and the airflow direction set Are outdoor ambient temperature not in operation range It the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation ria...

Page 30: ...mmunication may be disabled if an electronic starter type fluorescent lamp such as inverter type lamps The remote controller may not function correctly if the transmitter is exposed to direct sunlight...

Page 31: ...shop immediately The power cord is abnormally hot or damaged An abnormal sound is heard during operation The safety breaker a fuse or the earth leakage breaker cuts off the operation frequently A swi...

Page 32: ...RTAGE U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE U4 FAILURE OF TRANSMISSION BETWEEN INDOOR UNIT AND OUTDOOR UNIT INDOOR UNIT A1 INDOOR PCB DEFECTIVENESS A5 HIGH PRESSURE CONTROL OR FREEZE UP PROTECTO...

Page 33: ...MEMO 01_EN_3P322795 1C indd 27 12 3 2012 12 00 42 PM 32...

Page 34: ...MEMO 01_EN_3P322795 1C indd 17 12 3 2012 12 00 09 PM 33...

Page 35: ...MEMO 01_EN_3P322795 1C indd 27 12 3 2012 12 00 42 PM 34...

Page 36: ...Quick Reference HEAT DRY FAN FAN ONLY COOL AUTO COOL DRY HEAT FAN ONLY FAN The two dimensional bar code is a manufacturing code 3P705032 4 HT M22N095 2211...

Page 37: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS DTXF60T2VMA DTXF71T2VMA...

Page 38: ...operation Page 14 01_EN_3P322795 1C indd 1 12 3 2012 11 59 18 AM OUTDOOR UNIT QUIET OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit This function is useful when you need to co...

Page 39: ...WERFUL Operation 17 Adjusting the Airflow Rate 19 ECONO Operation 12 OFF TIMER Operation 20 ON TIMER Operation 21 Care Care and Cleaning 22 Troubleshooting Troubleshooting 27 AUTO DRY COOL HEAT FAN ON...

Page 40: ...efrigerant other than the one indicated on the outdoor unit R32 when installing moving or repairing Using other refrigerants may cause trouble or damage to the unit and personal injury To avoid electr...

Page 41: ...t Leaves are a hotbed for small animals which can enter the unit Once inside the unit such animals can cause malfunctions smoke or if they come into contact with electrical parts Do not place objects...

Page 42: ...Room temperature sensor It detects the air temperature around the unit Display ON OFF Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a sho...

Page 43: ...t Air inlet back and side Refrigerant piping and inter unit wiring Model name plate Earth terminal inside Drain hose Outdoor temperature sensor back Earth terminal inside Refrigerant piping and inter...

Page 44: ...ction is shown with its displays on for the purpose of explanation TEMPERATURE adjustment buttons It changes the temperature setting Page 10 OFF button Press this button to stop operation Page 9 POWER...

Page 45: ...atteries off The batteries will last for approx 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries...

Page 46: ...t is recommended to use another heating appliance in r The heat pump system heats the room by circulating hot air around all parts of the room After the start of HEAT operation it takes some time befo...

Page 47: ...Notes on the operating conditions The air conditioner always consumes a small amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for...

Page 48: ...e LCD ATTENTION when th Always use a remote controller to adjust the angles of the flaps If you attempt to move the flaps forcibly by hand ey are swinging the mechanism may be broken Hold the knob and...

Page 49: ...indoor unit quiet ope When the airflow is set to ration will start and the noise from the unit will become quiete In indoor unit quiet operation the airflow rate is set to a weak level If the temperat...

Page 50: ...n from before COMFORT AIRFLOW operation The flap position will change preventing air from blowing directly on the occupants of the room POWERFUL operation and COMFORT AIRFLOW operation cannot be used...

Page 51: ...HEAT 2 0 C in COOL 2 0 C in DRY operation from set temperature When the room temperature exceeds 30 0 C the operation changes the temperature 1 0 C in COOL 1 0 C in DRY operation from set temperature...

Page 52: ...ending on the clothes the people are wearing if there are no movements of the people in the area Due to the position of the sensor people might be exposed to the airflow of the indoor unit if they are...

Page 53: ...h ECONO or OUTDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing causes the settings t...

Page 54: ...breaker may trip if the air conditioner operate with its maximum capacity The maximum power consumption of the air conditioner is limited by using ECONO operation The circuit breaker will hardly trip...

Page 55: ...CONO operation is a function which enables efficient operation by limiting the power consumption of the outdoor unit operating frequency ration functions in AUTO COOL DRY and HEAT operation POWERFUL a...

Page 56: ...FAN ONLY and DRY operation POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time Priority is given to the function of whichever button is pressed last Even the operation...

Page 57: ...by 1 hour The TIMER lamp lights Setting time can be increase to 12 hours maximum orange To cancel OFF TIMER operation Press The TIMER lamp goes off NOTE Notes on TIMER operation When operating the un...

Page 58: ...amp goes off To combine ON TIMER and OFF TIMER A sample setting When setting while unit is operating for combining the 2 timers is shown below Example Turn off unit in the next 1 hr Turn on unit in th...

Page 59: ...Only neutral detergent may be used If dirty Table 1 BAFP094A43 BAFP094A41 BAFP046A41 KAF970A46 Cleaning Replacement Once every 6 months Once every 3 years To purchase the filters Table 1 or to purchas...

Page 60: ...ward you This will disconnect the front panel shaft on one side Disconnect the front panel shaft on the other side in the same manner Clean the front panel 2 Attach the front panel 3 Align the front p...

Page 61: ...sh the air filters with 2 water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks Air filter 2 Pull down 1 Push If the dust does not come off easily Wash the a...

Page 62: ...sides and the center This lter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the lter when removing water from it Do n...

Page 63: ...art Fan only operation 2 After operation stops turn off the breaker for the room air conditioner 3 4 Take out batteries f Clean the air filters and set them again Operate the FAN only for several hour...

Page 64: ...ard A sound like a ow of water This sound is generated because the refrigerant in the air conditioner is owing This is a pumping sound of the water in the air conditioner and heard when the water is p...

Page 65: ...h t e r A approp Are the airflow rate and the airflow direction set Are outdoor ambient temperature not in operation range It the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation ria...

Page 66: ...mmunication may be disabled if an electronic starter type fluorescent lamp such as inverter type lamps The remote controller may not function correctly if the transmitter is exposed to direct sunlight...

Page 67: ...shop immediately The power cord is abnormally hot or damaged An abnormal sound is heard during operation The safety breaker a fuse or the earth leakage breaker cuts off the operation frequently A swi...

Page 68: ...RTAGE U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE U4 FAILURE OF TRANSMISSION BETWEEN INDOOR UNIT AND OUTDOOR UNIT INDOOR UNIT A1 INDOOR PCB DEFECTIVENESS A5 HIGH PRESSURE CONTROL OR FREEZE UP PROTECTO...

Page 69: ...MEMO 01_EN_3P322795 1C indd 27 12 3 2012 12 00 42 PM 32...

Page 70: ...MEMO 01_EN_3P322795 1C indd 17 12 3 2012 12 00 09 PM 33...

Page 71: ...MEMO 01_EN_3P322795 1C indd 27 12 3 2012 12 00 42 PM 34...

Page 72: ...Quick Reference HEAT DRY FAN FAN ONLY COOL AUTO COOL DRY HEAT FAN ONLY FAN The two dimensional bar code is a manufacturing code 3P705032 5 HT M22N096 2211...

Reviews: