ETS1 ver. 1.22
The ETS1 is reset; all data is erased and the original settings are restored! ONLY TO
BE DONE BY AUTHORIZED PERSONNEL!
Protocol
Normal >
Short >
Ext. dump >
Choose protocol (for transmitting data to a PC):
Normal:
Standard values, set on normal.
Short:
Sends 34 bytes. Use with Skotselv radios.
Ext dump:
Sets a protocol that will give extended information when reading the
tags.
Eline
< Reset L1
|
0 | 0
< ||||||| >
With this function you may move the finishing line electronically by adjusting the
loops’ amperage. Do not try this if you’re not sure of what you are doing!
You may reset the amperage by choosing ‘Reset L1’.
Check the loops’ amperage if the loops don’t function as they should. The
amperage should ideally be ca. 2300 (+/- 100). If the amperage is less than 1500, the
loop will not function and must be reset.
Page
12