Reference Manual
00809-0100-4860, Rev BF
Troubleshooting
May 2019
84
Rosemount 8600 Vortex Flow Meter
A. Housing adapter screws
B. Housing adapter
C. Housing base screw
D. Ground connection
E. Electronics housing
F. Coaxial cable nut
G. Conduit adapter (optional-supplied by customer)
5.
Loosen the conduit adapter (or cable gland) from the housing adapter.
Attach the coaxial cable
1.
Route the coaxial cable through the conduit (if you are using conduit).
2.
Place a conduit adapter over the end of the coaxial cable.
3.
Remove the housing adapter from the electronics housing (if attached).
4.
Slide the housing adapter over the coaxial cable.
5.
Remove one of the four housing base screws that is in closest proximity to the
ground connection.
6.
Re-install the housing base screw by passing it through the ground connection.
7.
Attach and securely tighten the coaxial cable nut to the connection on the
electronics housing.
Figure 5
-
11. Remote Electronics Exploded View
D
B
A
E
F
C
G