Install the terminal block
1.
Align the socketed holes on the back side of the terminal block over the pins
protruding from the bottom of the housing cavity in the terminal block side of the
electronics housing.
2.
Slowly press the terminal block into place. Do not force the block into the housing.
Check the screw alignment if it does not glide into place.
3.
Tighten the three captive screws to anchor the terminal block.
4.
Connect the wires to the appropriate field terminals.
5.
Reinstall and tighten the transient ground screw if you have the transient option
(Option T1).
6.
Screw on and tighten the cover.
5.6.2
Replacing the electronics boards
The Rosemount 8600D electronics boards may need to be replaced if they have been
damaged or otherwise become dysfunctional. Use the following procedures to replace
electronics boards in the Rosemount 8600D. You will need a small Phillips head screwdriver
and pliers.
Note
The electronics boards are electrostatically sensitive. Be sure to observe handling
precautions for static-sensitive components.
Note
Remove power before removing the electronics cover.
Remove the electronics boards
1.
Turn off the power to the Rosemount 8600D.
2.
Unscrew and remove the electronics board compartment cover. (Unscrew and
remove the LCD cover if you have the LCD option).