Product Certifications
Product Certifications
July 2016
Reference Manual
00809-0100-4728, Rev MB
ND
ATEX Dust
Certification: KEMA 99ATEX8715X
Standards: EN 61241-0:2006, EN 61241-1:2004
Markings:
II 1 D, Ex tD A20 IP66 T95°C
1180
Special Conditions for Safe Use (X):
None
IECEx Certifications
I7
IECEX Intrinsic Safety
Certificate: IECEx BAS 12.0069X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2007
Markings: Ex ia IIC T6…T4 Ga
See Certificate (
)
Special Conditions for Safe Use (X):
1. The apparatus must be installed in an enclosure which
affords a degree of protection of at least IP20
2. Non-metallic enclosures must have a surface resistance of
less than 1Gohm
3. Light alloy or zirconium enclosures must be protected from
impact and friction when installed
N7
IECEX Type n (with enclosure)
Certification: IECEx BAS 07.0055
Standards: IEC 60079-0: 2004, EN60079-15: 2005
Markings: Ex nL IIC T5 Gc (-40 °C
≤
Ta
≤
70 °C)
NG
IECEX Type n (without enclosure)
Certificate: IECEx BAS 12.0070U
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T6…T5 Gc
Vmax = 45 volts max
Temperature limitations – T6 (-60 °C
≤
Ta
≤
40 °C), T5 (-60 °C
≤
Ta
≤
85 °C)
Specific Condition for Safe Use (X):
1. The component must be installed in a suitable certified
enclosure such that it is afforded a degree of protection of at
least IP54 in accordance with IEC 60529, IEC 600790, and IEC
60079-15.
E7
IECEx
Flameproof
Certification: IECEx KEM 09.0015X
Standards: IEC 60079-0: 2004, IEC 60079-1: 2007
Markings: Ex d IIC T6 Gb (-40 °C
≤
Ta
≤
65 °C)
Specific Condition for Safe Use (X):
1. For information on the dimensions of the flameproof joints
the manufacture shall be contacted.
NK
IECEX Dust
Certification: IECEx KEM 09.0015X
Standards: IEC 61241-0:2004, IEC 61241-1:2004
Markings: Ex tD A20 IP66 T95°C
Special Conditions for Safe Use (X):
None
Combinations of certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
K1
Combination of E1, I1, N1, and ND
K5
Combination of E5 and I5
K6
Combination of E6 and I6
K7
Combination of E7, I7, NK, and N7
KA
Combination of E1, I1, E6, and I6
KB
Combination of E5, I5, I6, and E6
KC
Combination of E5, E1, I5, and I1
KD
Combination of E5, I5, E6, I6, E1, and I1
B.2.3 Other certifications
Shipboard
SBS
American Bureau of Shipping (ABS)
Certificate: 00-HS145383/1-PDA
Standards: ABS Rules:2008 Steel Vessels Rules 1-1-4/7.7,
4-8-3/1.7
Intended Service: Measurement of Pressure, Flow and Level
for Liquid, Gas and Vapor Applications on ABS
Classed Vessels, Marine and Offshore Installations
B.3 Rosemount 644 with F
OUNDATION
Fieldbus and Profibus PA
B.3.1 European Union Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found at
www.EmersonProcess.com.
B.3.2 Hazardous Locations Certificates
North American Certifications
Factory Mutual (FM) Approvals
I5
FM Intrinsically Safe
Intrinsically Safe FISCO for use in Class I, II, III, Division 1,
Groups A, B, C, D, E, F, and G; when installed per control
drawing 00644-2075.
Temperature Code: T4A (T
amb
= – 50 °C to 60 °C).
Nonincendive for use in Class I, Division 2, Groups A, B, C, and
D.
Temperature Code: T5 (T
amb
= – 50 °C to 85 °C);
T6 (T
amb
= – 50 °C to 70 ° C) when installed per Rosemount
control drawing 00644-2075
Summary of Contents for Rosemount 644 HART
Page 2: ......
Page 16: ...6 Reference Manual 00809 0100 4728 Rev MB Introduction July 2016 Introduction ...
Page 86: ...76 Reference Manual 00809 0100 4728 Rev MB Troubleshooting July 2016 Troubleshooting ...
Page 138: ...128 Reference Manual 00809 0100 4728 Rev MB Index July 2016 Index ...
Page 139: ......