4. Loosen the nut that connects the transmitter head to the probe slightly.
60 mm
5. Screw the adapter into the process connection.
52 mm / 60 mm
6. Rotate the transmitter head so the device display faces the desired direction.
7. Tighten the nut.
60 mm
Torque 30 Lbft (40 Nm)