2.7
Probe selection guide
Use the following guidelines to choose appropriate probe for your Rosemount 3308 Series
transmitter:
Table 2-1: Probe Selection Guide
G=Good, NR=Not Recommended, AD=Application Dependent (consult factory)
Flexible single lead
Rigid single lead,
segmented rigid
single lead
Flexible twin lead
Coaxial
Measurements
Level
G
G
G
G
Interface (liquid/
liquid)
G
G
G
G
Process medium characteristics
Changing density
G
G
G
G
Changing dielectric
G
G
G
G
Wide pH variations
G
G
G
G
Pressure changes
G
G
G
G
Temperature changes G
G
G
G
Condensing vapors
G
G
G
G
Bubbling/boiling
surfaces
G
G
G
G
Foam (mechanical
avoidance)
NR
NR
NR
AD
Foam (top of foam
measurement)
AD
AD
AD
NR
Foam (foam and liquid
measurement)
AD
AD
AD
NR
Clean liquids
G
G
G
G
Liquid with dielectric
<2.0
AD
AD
AD
AD
G
G
NR
NR
Viscous liquids
G
G
AD
NR
Crystallizing liquids
AD
AD
NR
NR
Solids/Powders
NR
NR
NR
NR
Fibrous liquids
G
G
NR
NR
Transmitter overview
Reference Manual
February 2020
00809-0100-4308
20
Rosemount 3308 Series
Summary of Contents for Rosemount 3308A
Page 8: ...Contents Reference Manual February 2020 00809 0100 4308 viii Rosemount 3308 Series ...
Page 10: ...Introduction Reference Manual February 2020 00809 0100 4308 10 Rosemount 3308 Series ...
Page 22: ...Transmitter overview Reference Manual February 2020 00809 0100 4308 22 Rosemount 3308 Series ...
Page 74: ...Installation Reference Manual February 2020 00809 0100 4308 74 Rosemount 3308 Series ...
Page 96: ...Configuration Reference Manual February 2020 00809 0100 4308 96 Rosemount 3308 Series ...