146
Reference Manual
00809-0100-4107, Rev BA
Appendix A: Specifications and Reference Data
April 2013
Appendix A: Specifications and Reference Data
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
INMETRO Flameproof and Intrinsic Safety
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
★
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
★
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
★
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5,
and I6)
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
★
ATEX Type n
★
IECEx Type n
★
ATEX Dust
★
Sensor Fill Fluid and O-ring Options
Standard
Standard
L1
Inert Sensor Fill Fluid
★
L2
Graphite-Filled (PTFE) O-ring
★
LA
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
★
Display and Interface Options
Standard
Standard
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Transient Protection
Standard
Standard
T1
(9)
Transient terminal block
★
Manifold for Remote Mount Option
Standard
Standard
F2
3-Valve Manifold, Stainless Steel
★
F6
5-Valve Manifold, Stainless Steel
★
Alarm Limit
Standard
Standard
C4
(10)(11)
NAMUR Alarm and Saturation Levels, High Alarm
★
NAMUR Alarm and Saturation Levels, Low Alarm
★
CR
Custom Alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
Custom Alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT
Low Alarm (standard Rosemount alarm and saturation levels)
★
PlantWeb Control Functionality
Standard
Standard
A01
F
OUNDATION
fieldbus Advanced Control Function Block Suite
★
Hardware Adjustments
Standard
Standard
D4
Zero and Span Hardware Adjustments
★
DZ
Digital Zero Trim
★
Ground Screw
Standard
Standard
V5
(12)
External Ground Screw Assembly
★
HART Revision Configuration
Standard
Standard
(13)
Configured for HART Revision 5
★
(14)
Configured for HART Revision 7
★
Typical Model Number: 2051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5
Table 15. Rosemount 2051CFC Compact Flowmeter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.