1592025050 iProChill v2.5 10D00 AG v1.3 GB 18.02.2016.docx
iProCHILL
103/205
The sanitary water set point is editable.
Press
button
for 1 second can enable/disable the sanitary water function.
The sanitary water function status can be:
DIS
disabled by parameter setting
Dis by key
disabled by keyboard
Not requested
not needed
Doing dF
defrost in progress
Changing state
requested but not start yet, in inversion valve changing phase.
ON
activated
In Antilegionella cycle screen, relevant probes value, status and count down time will display.
The Antilegionella set point and the activate time is editable.
The antilegionella function status can be:
DIS
disabled by parameter setting
Not active
deactive
Running
active
In Solar panel screen, relevant probes value and output status will display.
The Solar panel set point is editable.
The solar panel working status can be:
Not active
Active