100-412-183 REV. 13
57
5.3.8
Available Digital Input Functions
Table 5.6
Available Digital Input Functions
Function
Description
Cable Detect
Disables ultrasonics if 24 V signal is removed when using 0 V
negative logic (active low) for the external Start input. Used to
prevent ultrasonics from coming on if a cable is removed.
Display Lock
Locks the front panel display controls
External Horn
Scan
Starts horn scan sequence.
External Reset
Resets alarm conditions.
External Seek
Activates ultrasonic energy at 10% amplitude for the purpose of
finding the ultrasonic stack resonant frequency.
External Start
Activates ultrasonic energy at the currently set amplitude.
NOTICE
DCX S Power Supply must be in ready mode before External Start.
WARNING
When using 0 V to activate ultrasonics (External Start signal), it is
recommended to assign one input as Cable Detect to prevent sonics
from activating if 24 V is lost by accident.
External Test
Performs a test cycle.
Memory Clear
Centers the power supply start frequency.
Summary of Contents for DCX S
Page 4: ...iv 100 412 183 REV 13 ...
Page 22: ...12 100 412 183 REV 13 ...
Page 36: ...26 100 412 183 REV 13 ...
Page 47: ...100 412 183 REV 13 37 4 3 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Page 50: ...40 100 412 183 REV 13 ...
Page 54: ...44 100 412 183 REV 13 Figure 5 1 DCX S Power Supply Benchtop Dimensional Drawing ...
Page 86: ...76 100 412 183 REV 13 ...
Page 87: ...100 412 183 REV 13 77 Chapter 6 Converters and Boosters 6 1 Converters and Boosters 78 ...
Page 120: ...110 100 412 183 REV 13 ...
Page 137: ...100 412 183 REV 13 127 8 5 Circuit Diagram Figure 8 2 Interconnect Diagram Power Supply ...
Page 144: ...134 100 412 183 REV 13 ...
Page 145: ...100 412 183 REV 13 135 Appendix A Timing Diagrams A 1 Timing Diagrams 136 ...
Page 147: ...100 412 183 REV 13 137 Appendix B Signal Diagrams B 1 Signal Diagrams 138 ...
Page 154: ...144 100 412 183 REV 13 ...