50
100-412-183 REV. 13
5.3.1
Mount the Power Supply
The cable lengths are limited based on the operating frequency of the welding system.
Performance and results can suffer if the RF cable is crushed, pinched, damaged or
modified. Contact your Branson Representative if you have special cable requirements.
Do not place the power supply on the floor or in other locations that will allow dust, dirt or
contaminants to be drawn into the power supply.
5.3.2
Horizontal (Benchtop) Mounting
The Horizontal DCX S Power Supply is designed to be placed on a workbench (rubber feet
on bottom) within cable-length limits of the stack. It has one fan which draws cooling air
from the left side to the right side, which must be free from obstruction. The controls on
the front of the power supply should be accessible and readable for setup changes.
All electrical connections are made to the rear of the power supply, which should be
positioned in your workspace with adequate clearance, approximately 3 in (76.2 mm) or
more on either side, and 5 in (127 mm) to the rear) for cable access and ventilation. Do
not place anything on top of the power supply case.
For a dimensional drawing of the Horizontal DCX S Power Supply, see
Power Supply Benchtop Dimensional Drawing
5.3.3
Vertical Mounting
The Vertical DCX S Power Supply is designed to be mounted vertically (from the side or
back) within cable-length limits of the stack. It has one fan which draws cooling air from
the top to the bottom of the power supply, which must be free from obstruction. The
controls on the front of the power supply should be accessible and readable for setup
changes.
All electrical connections are made to the bottom of the power supply, which should be
positioned with adequate clearance (approximately 3 in (76.2 mm) or more on the top,
and 5 in (127 mm) to the bottom) for cable access and ventilation. Do not place anything
on top of the power supply case.
For dimensional drawings of the Vertical DCX S Power Supply, see figures
.
NOTICE
Special fan filter kits are available for use in dusty environments. See
Table 8.12 Other Items used with the DCX S Power Supply
.
NOTICE
Do not block exhaust and intake air circulation, which is needed to
maintain a safe operating temperature.
Summary of Contents for DCX S
Page 4: ...iv 100 412 183 REV 13 ...
Page 22: ...12 100 412 183 REV 13 ...
Page 36: ...26 100 412 183 REV 13 ...
Page 47: ...100 412 183 REV 13 37 4 3 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Page 50: ...40 100 412 183 REV 13 ...
Page 54: ...44 100 412 183 REV 13 Figure 5 1 DCX S Power Supply Benchtop Dimensional Drawing ...
Page 86: ...76 100 412 183 REV 13 ...
Page 87: ...100 412 183 REV 13 77 Chapter 6 Converters and Boosters 6 1 Converters and Boosters 78 ...
Page 120: ...110 100 412 183 REV 13 ...
Page 137: ...100 412 183 REV 13 127 8 5 Circuit Diagram Figure 8 2 Interconnect Diagram Power Supply ...
Page 144: ...134 100 412 183 REV 13 ...
Page 145: ...100 412 183 REV 13 135 Appendix A Timing Diagrams A 1 Timing Diagrams 136 ...
Page 147: ...100 412 183 REV 13 137 Appendix B Signal Diagrams B 1 Signal Diagrams 138 ...
Page 154: ...144 100 412 183 REV 13 ...