Figure 4-7: Security seal wire
Follow the steps below to seal the electronics enclosure.
Procedure
1. Rotate the end cap clockwise, fully closing and compressing the end cap seal. Install
the security latch using a 3mm Allen wrench.
2. Install the security seal wire into and through one of the two holes in the end cap
and the housing. Choose holes that minimize counterclockwise rotation of the end
cap when the security wire is taut (maximum wire diameter 2.0 mm, .078 inch).
3. Adjust the security wire, removing all slack and thread into the lead seal.
4. Cut the ends of the wire to remove any excess wire.
Prepare the turbine meter for use