Operating conditions for the liquid turbine
meter
Table 2-1: Operating conditions for the liquid turbine meter
Parameter type
Description
Fluid phase
Liquid
Fluid(s) measured
•
Low/medium viscosity crude oils and condensates
•
Refined products and intermediates (e.g.:
gasoline,
diesel, kerosene, light fuel oils, jet fuel, LPG, butanes,
naphtha, alkylate, reformate, straight run gasoline, cat-
cracked gasoline
)
•
Petrochemicals (e.g.:
benzene, toluene, xylenes, cumene,
olefins, pyrolysis gasoline
)
•
Natural gas liquids
Process temperature
(Carbon steel flanges)
-29 ºC to 60 ºC (-20 ºF to 140 ºF)
Optional process temperature
(Carbon steel flanges)
-29 ºC to 204 ºC (-20 ºF to 400 ºF)
Process temperature
(Stainless steel flanges)
-40 ºC to 60 ºC (-40 ºF to 140 ºF)
Optional process temperature
(Stainless steel flanges)
-40 ºC to 204 ºC (-40 ºF to 400 ºF)
Fluid static pressure
The maximum working pressure for the Daniel Series 1500
Liquid Turbine Meter is based on the temperature/
pressure rating of the ANSI B16.5 flanges. For maximum
working pressures at intermediate temperatures refer to
ANSI B16.5.
Fluid flow rate
100 BPH – 60000 BPH
Pressure drop
At maximum flow of normal flow range on water 4 psi.
Ambient temperature
-40 ºC to 60 ºC (-40 ºF to 140 ºF) (T
amb
is an electrical
specification)
Note
Remote mount the LME when the ambient temperature is above 60 °C (140 °F).
User manual
Operating conditions and specifications
P/N 3-9008-515
March 2019
User manual
41
Summary of Contents for Daniel Series
Page 2: ...2 ...
Page 11: ...Part I Plan User manual Plan P N 3 9008 515 March 2019 User manual 11 ...
Page 69: ...Part II Install User manual Install P N 3 9008 515 March 2019 User manual 69 ...
Page 79: ...Part III Operate User manual Operate P N 3 9008 515 March 2019 User manual 79 ...
Page 83: ...Part IV Maintain User manual Maintain P N 3 9008 515 March 2019 User manual 83 ...
Page 105: ...User manual P N 3 9008 515 March 2019 User manual 105 ...