9.4
Mechanical assembly
Protection for rotor blades from rough handling as blade position is critical to turbine
meter performance.
Use appropriate torque values to reinstall the shaft nut and to avoid equipment damage or
inaccurate turbine meter operation.
Important
The shaft nut can only be reused up to five times. Replace as needed.
Table 9-1: Torque requirements for shaft nut reinstallation
Turbine meter size
Torque requirement
3
7.9 n-m (70 in-lbs)
4
11.3 n-m (100 in-lbs)
6
67.7-81.3 n-m (50-60 ft-lbs)
8
67.7-81.3 n-m (50-60 ft-lbs)
10
81.3-95 n-m (60-70 ft-lbs)
12
95-122 n-m (70-90 ft-lbs)
16
108-135 n-m(80-100 ft-lbs)
18
108-135 n-m (80-100 ft-lbs)
20
108-135 n-m (80-100 ft-lbs)
24
108-135 n-m (80-100 ft-lbs)
9.4.1
Assemble internal meter housing components -NPS 3
through 24
Procedure
1. Install the upstream hanger assembly in the inlet side. Secure the upstream hanger
by tapping the hanger assembly with a plastic hammer.