Maintenance and Troubleshooting Manual
Section 3: Meter maintenance
3-9000-772 Rev B
January 2018
Replacing the Acquisition Module
67
3.4.7
Replacing the Acquisition Module
Procedure
1.
Disable electrical power to the meter.
2.
Refer to
Table 3-4
for the tools required to complete this procedure.
3.
Attach a plate to the remote mount pipe or rigid structure to support the Base
Enclosure.
4.
If the meter is equipped with security seals, remove the seals from the socket head
screws in the Bracket/Cover.
Figure 3-22 Bracket/Cover plate removal
5.
Use a 7/16 inch (11mm) wrench and remove the four hex head bolts and split lock
washers securing the Base Enclosure to the Bracket/Cover.
6.
Carefully lower the Base Enclosure and rest it on the support plate.
A. Transmitter electronics enclosure
A.
B. Socket head screws with hole for security wire
C.
E.
F.
B.
C. Bracket/Cover with synchronization cable
D. Acquisition cable
D.
E. Base remote mount enclosure with Acquisition Module
F. Support plate