32
SI-I/O User Guide
Issue Number: 3
Figure 8-5 Analog input 3 and analog output 1
mm.ppp
mm.ppp
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown in their default settings
??.???
??.???
x(-1)
T9 Analog
input 3 destination
T9 Analog
input 3 invert
T9 Analog
input 3 offset
T9 Analog
input 3
maximum
T9 Analog
input 3
minimum
T9 digital input 7
Analog input 3 mode
T9 Analog
input 3 scaling
Analog input
3 current loop
loss
S.03.036
S.03.031
S.03.033
S.03.035
S.03.034
Analog input
3 destination
Any unprotected
variable parameter
T9 Analog
input 3
+
+
A/D
S.03.032
Volt IN
4-20 mA Low
4-20 mA Hold
20-4 mA Hold
0-20 mA
20-0 mA
4-20 mA Trip
20-4 mA Trip
4-20 mA
20-4 mA
20-4 mA Low
T9
S.01.017
11
10
9
8
7
6
5
4
3
2
1
T11 Analog
output 1
scaling
T11 Analog
output 1 source
T11 Analog
output 1
??.???
??.???
S.03.036
Any unprotected
variable parameter
A/D
T11 digital input 8
DAC output 1 mode
Volt OUT
20-4 mA
0-20 mA
20-0 mA
4-20 mA
T11
S.01.018
5
4
3
2
1
S.03.007
S.03.003
S.03.037
S.03.005